66
4-Wire TIMS
4-Wire TIMS Wideband
Use the 600 Ohm pull-down menu and select 100 or 135 Ohm termination. Wideband
mode is typically used for DDS, ISDN, HDSL, T1 and XDSL copper qualifications.
Measurements
Transmit & Receive
Receive frequency and level is displayed next to RX and is displayed in Hz and dBm.
To change the TX frequency, tap the up or down arrows. The frequency will step
up/down by 200Hz in voice-band modes and 20kHz in wide-band modes. Change the
step size by highlighting the step frequency (200/20k) and enter the desired step fre-
quency and press
DONE
. To transmit a specific frequency tap on the frequency box
(right of TX), use the keyboard to enter the desired frequency then press Done To
change the TX level use the up/down arrow or enter the desired level by highlighting
the (0) and entering a level (number) followed by pressing Done.
Sweep Button
The user can select a start and stop frequency along with a step frequency. To start a
sweep test press the Sweep button. The frequency will increment by the step frequen-
cy that is entered (200Hz) every 2 seconds. To stop the sweep function, press the
STOP
button.
Quick Tones
The Quick tones pull-down includes the most common frequencies to test. In
voiceband (600, 900, 1200
Ω) these are 404, 1004, 2804, 2713, 1804, 3204, 1913, and
2413Hz. In Wideband (100 and 135
Ω) these are DDS, HDSL, and XDSL frequencies
Summary of Contents for Greenlee Communications DataScout 10G
Page 1: ...2015 Greenlee Communications 52071568 Users Manual DataScout 10G 10Gx Version 11...
Page 2: ......
Page 4: ......
Page 12: ......
Page 16: ......
Page 22: ......
Page 26: ......
Page 40: ......
Page 58: ......
Page 66: ......
Page 86: ......
Page 102: ......
Page 114: ......
Page 115: ......