EK1240KLX Battery-powered Crimping Tool

LCD Screen

This tool has an LCD screen, which displays informa-

tion about the tool. Turn on the screen by inserting the 

battery and jogging the tool. If there are any problems 

with the tool, an error code appears.

Error Code Meaning

 1

Overcurrent fuse

 2

Overcurrent comparator

 3

Overheated circuit board

 4

Overheated battery

 5

Battery empty; operation stops

 6

Faulty crimp; complete cycle

 7

Faulty crimp; incomplete cycle

 8

Low battery

 9

Battery empty; tool won’t run

10

Real-time clock battery low

11

Tool deactivated

12

Service necessary

13

Real-time clock not found

14

Bluetooth

®

 unit not found

15
16

Pressure sensor not found

17

Burst pressure exceeded

18

Battery temperature too low

If there is no error code, cycle through the various 

 displays using the left and right buttons on either side of 

the screen. There are seven displays in total. 

Display Information Shown

1

Bluetooth

®

 status, battery charge, current 

pressure, max. pressure

2

Firmware, available firmware update, 

serial number

3

Current user. Press and hold both buttons to 

change user, select with right button, and confirm 

by jogging the tool.

4
5
6

Cycles until next service

7

Since manufacturing: operating hours, capacity, 

number of cycles

Summary of Contents for 783310610465

Page 1: ...ee Textron Inc 4 17 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register this product at www greenlee com EK1240KLX GATOR...

Page 2: ...t Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This manual and any markings on the tool provide information for avoiding hazards and unsafe practices related t...

Page 3: ...ure to observe this warning could result in severe injury or death Wear eye protection when operating or servicing this tool Failure to wear eye protection could result in serious eye injury from flyi...

Page 4: ...trical components are soaked Use this tool for the manufacturer s intended purpose only Failure to observe these precautions may result in injury or property damage Do not allow anything to contact th...

Page 5: ...e 12 tons 106 kN Hydraulic Oil 52057878 biodegradable hydraulic fluid Recommended Operating Temperature Range 5 F to 122 F 15 C to 50 C Crimping Capacities Crimping Range 8 AWG to 750 kcmil 10 mm2 to...

Page 6: ...wever air drying is recommended before use if the tool becomes soaked Damage may result when the tool is operated prior to thorough drying when electrical components are soaked Use this tool for the m...

Page 7: ...tion evenly spaced First Compression Crimping Direction SIDE A evenly spaced Crimping Direction SIDE B evenly spaced First Compression SIDE A First Compression SIDE B 7 Using the sequence illustrated...

Page 8: ...attery empty tool won t run 10 Real time clock battery low 11 Tool deactivated 12 Service necessary 13 Real time clock not found 14 Bluetooth unit not found 15 16 Pressure sensor not found 17 Burst pr...

Page 9: ...the crimp ing tool head when crimping Failure to observe these warnings could result in severe injury or death Relief valve adjustments must be done by an authorized service center Daily Before use 1...

Page 10: ...00 435 0786 for warranty service or repair Motor is inoperative Low or uncharged battery Try known charged battery Inoperative battery may be discharged or may have reached life expectancy Broken swit...

Page 11: ...8 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc is a subsidiary of Textron Inc USA Tel 800 435 0786 Fax 800 451 2632 Canada Tel 800 435 0786 Fax 800 524 2853 International Tel 1 815 397 70...

Reviews: