27
10. TROUBLESHOOTING
Check as noted below if there is anything wrong.
If the trouble cannot be correct, call the dealer.
Sympton
Check
Cause
Power switch does
not turn on.
*
Power lamp not lit.
*
Short bar coming off.
*
Overvoltage protection
worked.
*
Power cord disconnected or
connected defectively.
*
Input switch defective.
*
Input fuse blown.
*
Rear-panel short bar
disconnected or loose.
*
Voltage set too low.
Output voltage is zero
or low.
*
Short bar coming off.
*
Constant-voltage/current
Lamps do not switch.
*
Ammeter deflects with
output off.
*
Oscillating
*
Short bar installed defectively.
*
Circuit defective.
*
Output diode broken.
*
Oscillation by remote sensing.
Output is excessive.
*
Short bar coming off.
*
Output voltage/current
do not fall.
*
Short bars 1 – 2 and 6 – 7 come
off.
*
Power transistor or control
circuit defective.
Output is not steady.
*
Short bar coming off.
*
Input voltage wrong.
*
Oscillating
*
Sensing terminal
floating.
*
Strong magnetic/electric
fields near-by.
*
Other
*
Short bar installed defectively.
*
Out of the rated input voltage
range.
*
Oscillation by special load.
*
Proper connection of sensing
terminal.
*
Keep away from oscillation
sources.