25
output of this product is turned on.
Note 1 : The DIN connector pins are electrically connected to the positive output terminal.
Thus, be sure to use them in the float condition.
Note 2 : A 7-pin connector cable for connecting the GP-IB adapter <GP-600B> cannot be
connected to the 5-pin connector shown above. To turn on add off the output or
make interruptions in the CV/CC mode or power off mode, the external I/O unit
<OP-18-PD> need be installed.
(The OP-18-PD is a factory option, since the PD-A power supply unit need be
remade internally to install the OP-18-PD.)
Note 3 : If the external I/O unit <OP-18-PD> is installed on the PD-A power supply unit, the
above-shown connector is changed into the 7-pin DIN connector exclusive for
the <GP-600B>. Thus, the output cannot be turned on or off using the external
contact signals.
3 5
1
4
2