19
6-3-1. Storing preset voltage/current values
Operation procedures
1. Press the PRESET key of the preset memory (1, 2, 3 or 4) where the set voltage and current
should be stored. The LED is lit up in green.
2. Set voltage and current values to be stored.
3. Press the MEMORY key. The LED of the PRESET key pressed in step 1 blinks in green.
When the PRESET key whose LED is blinking in green is pressed, the LED is lit up in green and
the set voltage and current are stored in that preset memory. To cancel the memory operation,
press the MEMORY key again while the LED of the PRESET key is blinking in green.
The blinking LED is lit up and the memory operation is canceled.
<Precautions>
・
Note that it is impossible to recall the voltage or current set with the rotary encoder unless they
are stored in the preset memory through the operation described in section 6-3-1 "Storing set
voltage and current in preset memory".
6-3-2. Recalling preset values
・
The set voltage and current stored in preset 1 to preset 4 by pressing the PRESET keys 1 to 4.
6-3-3.
Storing values in preset memory in MAIN OUTPUT key on mode
Operation procedures
1. Press the LIMIT key while the MAIN OUTPUT key is on.
2. Set voltage and current are displayed on the voltage and current indicators.
3. Press the PRESET key of the preset memory whose data should be changed. The LED of some
PRESET key (1 to 4) is lit. Note that no data may be written in the preset memory whose LED is lit.
4. The LED of the PRESET key pressed in step 3 blinks. The voltage and current stored in that preset
memory are displayed.
5. Change the displayed voltage and current to intended values.
6. Press the PRESET key whose LED is blinking. The LED goes out and the voltage and current
set in step 5 are written in that preset memory. (To cancel the memory operation, press the
MEMORY key without pressing the PRESET key whose LED is blinking.) On completion of
operation, the set voltage and current are displayed on the voltage and current indicators.
(Condition in step 2)
6-3-4. Copying preset values
Operation procedures
1. Press the PRESET key of the memory where the original voltage and current are stored.
The LED of the key is lit up in green.
2. Press the MEMORY key. The LED of the PRESET key pressed in step 1 blinks in green.
3. Press the PRESET key of the memory where the data should be copied. The LED of the PRESET
key blinking in green goes out, and the LED of the pressed PRESET key is lit up in green.
The set voltage and current are copied in the preset memory whose LED is lit in green.