Speech Dialler
Installation Manual
INS232
7
Connections to the Control Panel
Before making any connection to the
Speech Dialler
isolate
ALL
power from the
control panel (AC mains and battery).
Do not continue if there is power still present
on the control panel.
+12V & 0V
These terminals must be connected to the 12V auxiliary power supply of the alarm
control panel.
Trigger 1 - 4
These terminals should be connected to the relevant outputs on the alarm control
panel. When the input is triggered the
Speech Dialler
will initiate the calling sequence
and play the relevant speech and/or text message. The diagram below show the
various wiring options for the trigger inputs:
N.C.
Loop
1
2
3
4 0V 12V
Trigger Inputs
1K
W
N.O.
Loop
1
2
3
4 0V 12V
Trigger Inputs
+12V when active
(+ve applied)
1
2
3
4 0V 12V
Trigger Inputs
Trigger Inputs programmed for +ve operation
N.C.
Loop
1
2
3
4 0V 12V
Trigger Inputs
1K
W
N.O.
Loop
1
2
3
4 0V 12V
Trigger Inputs
0V when active
(+ve removed)
1
2
3
4 0V 12V
Trigger Inputs
Trigger Inputs programmed for -ve operation
Tamp.
These terminals provide tamper protection for the
Speech Dialler
and should be
connected to the auxiliary tamper circuit on the alarm control panel.
OP1 & OP2
Two programmable switched –ve @100mA outputs.