Call-Abort:

 The 

Speech Dialler

 has several call-abort options, which include restoring 

the trigger input or by entering the operator’s passcode. When the unit is aborted it 
immediately shuts down and returns to its normal standby mode. 

Outputs:

 The 

Speech Dialler

 has programmable outputs that can be used to indicate 

the status of the unit. The outputs can also be programmed for “remote control”, this 
allows you to remotely turn outputs on and off with a touch-tone telephone. 

Listen-In Mode:

 The 

Speech Dialler

 has a listen-in mode, which switches the internal 

microphone to the telephone line so that you can hear activity at the protected site. 
The listen-in mode can be activated by the contact at the time of receiving a voice 
message or by calling into the 

Speech Dialler

 and using the Remote Access feature. 

Talkback Mode:

 The 

Speech Dialler

 has a talkback mode, which switches the internal 

loudspeaker to the telephone line so that you can talk to the protected site. The 
talkback mode can be activated by the contact at the time of receiving a voice 
message or by calling into the 

Speech Dialler

 and using the Remote Access feature. 

Memo:

 The 

Speech Dialler

 has a memo feature, which allows you to record up to 32 

seconds of audio. The memo feature can be accessed locally at the unit or remotely 
using a touch-tone telephone. When a new memo is recorded the unit will indicate it 
on the display and optionally give a beep. The memo feature can also be 
programmed to automatically record when a trigger input is activated. 

Remote Access:

 If enabled the 

Speech Dialler

 can be accessed remotely by dialling 

into the unit with a touch-tone telephone. Once connected you can turn on and off the 
two outputs, activate the listen-in or talkback mode, listen to the memo, or record a 
new memo. 

Context Sensitive Help:

 When programming or operating the 

Speech Dialler

 you can 

press the help key and the unit will scroll the relevant information on the display. 

 

 

ukpanels.com

Summary of Contents for Speech Dialler

Page 1: ...Speech Dialler Installation Manual Installation Manual Voice Text Dialler THANK YOU FOR VOTING TEXECOM ukpanels com...

Page 2: ...bile Network Alarm Control Panel Telephone Auxiliary Input Telephone Network Speech Dialler 4ghi 2abc 3def 7pqrs 5jkl 8tuv 0 6mno 9wxyz 1 Ready Intruder 3 PA 2 Fire 1 Aux 4 Contact 4 or Contact 3 or C...

Page 3: ...each message can be up to 32 seconds long Message 1 is related to trigger input 1 message 2 is related to trigger input 2 and so on Voice messages should therefore be recorded to reflect the type of a...

Page 4: ...mode which switches the internal loudspeaker to the telephone line so that you can talk to the protected site The talkback mode can be activated by the contact at the time of receiving a voice messag...

Page 5: ...carefully inserting a small flat blade screwdriver into each slot at the base of the unit Gently push the screwdriver to ease the retaining clips upward DO NOT LEVER OR TWIST Excessive force is NOT re...

Page 6: ...the Speech Dialler are described as either Safety Extra Low Voltage circuits SELV or Telecommunications Network Voltage circuits TNV It is important that the TNV connections are only connected to the...

Page 7: ...he calling sequence and play the relevant speech and or text message The diagram below show the various wiring options for the trigger inputs N C Loop 1 2 3 4 0V 12V Trigger Inputs 1KW N O Loop 1 2 3...

Page 8: ...A Bell ve Power Power Gardtec 800 Series D1 PA 12Hr ve 12V 0V Menvier TS400 TS410 Zone 4 Zone 5 ALM ve Aux Aux Menvier TS510 N A OP 2 OP 1 ve Aux Aux Menvier TS690R OP 1 OP 2 OP 3 ve Aux Aux Menvier N...

Page 9: ...g enough or the serial connection is required the Speech Dialler can be hard wired to the telephone socket as shown below 3 2 1 6 5 4 White Blue BT Master Jack NTE5 User accessible connections Cable t...

Page 10: ...ng initialisation mode 4 After the unit has finished initializing loading defaults the display will show 1 2 1 To select the programming mode enter the default passcode of 5 The display will show 345...

Page 11: ...MC Directive 89 336 EEC amended by 92 31 EEC and 93 68 EEC The CE mark indicates that this product complies with the European requirements for safety health environment and customer protection Warrant...

Page 12: ...ecom Limited Bradwood Court St Crispin Way Haslingden Lancashire BB4 4PW England Technical Support Tel 44 0 1706 234833 Tel 44 0 1706 234811 Fax 44 0 1706 213187 TEXECOM LTD 2000 2003 INS232 ukpanels...

Reviews: