7. 

Auxiliary Input

With the Auxiliary input enabled (JP8), a second detector with a normally 
closed relay output can be connected to the Premier External detector to give 
directional detection.  The order of activation required to give an alarm signal is 
set by the direction jumper (JP9).
When this is set to ‘1st’ the auxiliary detector must be activated first followed 
by the Premier External detector within 1 minute to give a valid alarm signal.
With the jumper set to 2nd, the Premier External detector must be activated 
followed by the auxiliary detector within 1 minute.
If directional detection is not required, disable the auxiliary input using JP8. 

AUX

Premier External PIR

AUX

Premier External PIR

JP8

ON

JP9

ALARM

NO 

ALARM

1st

2nd

NO 

ALARM

NO 

ALARM

JP9

ALARM

NO 

ALARM

1st

2nd

OFF

Supplier: 

Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4 4PW, UK.

Weee Directive

: Products marked with this symbol cannot be disposed of as unsorted municipal 

waste in the European Union. For proper recycling, return this product to your local 
supplier upon the purchase of equivalent new equipment, or dispose of it at designated 
collection points. For more information see: www.recyclethis.info.

RoHs Directive: 

RoHS Compliant. Hereby, Texecom declares that this device does not 

contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) 

or polybrominated depheny ethers (PBDE) in more than the percentage specified by EU directive, 
except exemptions stated in EU directive annex.

CE Directive:

 Hereby, Texecom declares that this device is in compliance with the essential   

requirements and other relevant provisions of Directive.

Maintenance:

 Test yearly by the installer

Warranty:

 2 year replacement warranty

Security grade: 

EN Grade 2  

Environmental class:

 Class IV 

Disclaimer:

 The Premier External TD is not a complete alarm system, but only its part. Therefore 

Texecom does not accept any responsibility or liability for any damage that is claimed to be a 
result of an incorrect functioning of the Premier External TD detector. Texecom reserves the right 
to change the specification without a prior notice.

Cer tificate Number: FM 35285

Summary of Contents for Premier External TD

Page 1: ...Premier External TD Installation Manual INS352 5...

Page 2: ...2 5 1 2 3 Remove the top cap and loosen screw screw retained in wall plate Push up head unit and remove Use a flat head screwdriver to lever out both sides of the terminal cover as shown 1 Accessing t...

Page 3: ...ees and swaying clothes on a clothes line Try to install the detector so its detection area is terminated by building fences etc This will reduce the effect of range variation caused by environmental...

Page 4: ...URFACE WIRING For surface wiring use the appropriate knockout in the top or bottom of the unit If wiring from the top use the knockouts in the top cap and run the cable down the cable channels and int...

Page 5: ...es with an outside diameter of 20 57mm Assemble the kit around the pole as shown and tighten the 4 bolts Hook the detector wall plate onto the kit and secure the remaining 2 bolts through the lower mo...

Page 6: ...P3 Alarm NO alarm relay normally open NC alarm relay normally closed TERMINAL BLOCK 12V 0V 9 16 VDC ALARM NO NC selectable relay output 18 50VDC 100mA Max TAMPER NC Relay output 18 50VDC 100mA Max RLE...

Page 7: ...esistor of the selected value as shown JP6 Selects the resistance across the alarm relay Equivalent to wiring a resistor of the selected value as shown TAMPER JP6 ALARM JP7 Night Mode Detector only op...

Page 8: ...ion 5m Coverage Position 2m Coverage Selected Range Side View Bottom of head unit To adjust the range of the detector rotate the circular section shown until the desired range is shown in the window N...

Page 9: ...12m 0m 12m 10m 8m 6m 4m 2m 0m 12m 10m 8m 6m 4m 2m Active detection coverage 90 90 90 45 45 Bottom of head unit Bottom of head unit Top View Top View Walk testing With the range sensitivity coverage a...

Page 10: ...with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment o...

Page 11: ...table to 8m 5m and 2m Alarm Output NC NO selectable relay Rated 50VDC 100mA 18 Tamper Detection Wall and case Sealed non mechanical switch Tamper Output NC relay Rated 50VDC 100mA 18 LED Indication Re...

Page 12: ...B4 4PW England Texecom Limited 2011 INS352 5 Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International...

Reviews: