background image

7

INS352-5

5. 

Range Adjustment - PIR

1.2m

2m

4m

6m

8m

10m

12m

0m

0m

1.2m

2m

4m

6m

8m

10m

12m

0m

0m

1.2m

2m

4m

6m

8m

10m

12m

0m

0m

1.2m

2m

4m

6m

8m

10m

12m

0m

0m

Position - 12m Coverage

Position - 8m Coverage

Position - 5m Coverage

Position - 2m Coverage

Selected Range

Side View

Bottom of head unit

To adjust the range of the detector, rotate the 
circular section shown until the desired range is 
shown in the window. 

Note: 

Range can vary due to environmental 

conditions. To reduce the risk of false alarms 
always select the lowest range possible for the 
installation.

Specified ranges are valid for nominal 1.2m 
mounting height.

Summary of Contents for Premier External TD

Page 1: ...Premier External TD Installation Manual INS352 5...

Page 2: ...2 5 1 2 3 Remove the top cap and loosen screw screw retained in wall plate Push up head unit and remove Use a flat head screwdriver to lever out both sides of the terminal cover as shown 1 Accessing t...

Page 3: ...ees and swaying clothes on a clothes line Try to install the detector so its detection area is terminated by building fences etc This will reduce the effect of range variation caused by environmental...

Page 4: ...URFACE WIRING For surface wiring use the appropriate knockout in the top or bottom of the unit If wiring from the top use the knockouts in the top cap and run the cable down the cable channels and int...

Page 5: ...es with an outside diameter of 20 57mm Assemble the kit around the pole as shown and tighten the 4 bolts Hook the detector wall plate onto the kit and secure the remaining 2 bolts through the lower mo...

Page 6: ...P3 Alarm NO alarm relay normally open NC alarm relay normally closed TERMINAL BLOCK 12V 0V 9 16 VDC ALARM NO NC selectable relay output 18 50VDC 100mA Max TAMPER NC Relay output 18 50VDC 100mA Max RLE...

Page 7: ...esistor of the selected value as shown JP6 Selects the resistance across the alarm relay Equivalent to wiring a resistor of the selected value as shown TAMPER JP6 ALARM JP7 Night Mode Detector only op...

Page 8: ...ion 5m Coverage Position 2m Coverage Selected Range Side View Bottom of head unit To adjust the range of the detector rotate the circular section shown until the desired range is shown in the window N...

Page 9: ...12m 0m 12m 10m 8m 6m 4m 2m 0m 12m 10m 8m 6m 4m 2m Active detection coverage 90 90 90 45 45 Bottom of head unit Bottom of head unit Top View Top View Walk testing With the range sensitivity coverage a...

Page 10: ...with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment o...

Page 11: ...table to 8m 5m and 2m Alarm Output NC NO selectable relay Rated 50VDC 100mA 18 Tamper Detection Wall and case Sealed non mechanical switch Tamper Output NC relay Rated 50VDC 100mA 18 LED Indication Re...

Page 12: ...B4 4PW England Texecom Limited 2011 INS352 5 Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International...