Premier Elite Series
Quick Start Guide
INS222-10
21
U
Ricochet Learn
B
/
O
*
Ricochet
®
Learn
Will go to the next available wireless zone starting at 9 or Press
to search. Learning always starts from the next available zone,
deleting ways starts from the highest zone learnt to the system. Use the
/
key to start the learn process for the device
R
/
R
Enters the Delete
Menu
/
To learn devices
*Where available.
Learning & Deleting Ricochet Devices
Introduction
Learn Devices from first power up
When the "Confirm Devices" menu appears check and make sure all
installed Keypads and Expanders are showing; press
/
and
/
again to confirm.
Providing the system has a
Ricochet
enabled expander installed,
the following will appear. The flow diagram shows the procedure to
learn devices:-
YES to Select:-
Learn Ricochet
Learn Device?
Zone ??? N?,E??
Power up Device!
N?,E?,D?? - 20s
Learn Device to
Zone ??? N?,E??
n
U
N
N
Device Type
Learn method
Premier Compact All
models
Pull battery tab or Insert battery
Impaq Contact &
Plus
Short learn pins and insert battery
Odyssey &
OdysseyX-W
Insert batteries and move Battery Jumper
to ON position
CO-W, OH-W & PA-
W
Pull battery tab or Insert battery
Premier Elite QD/XT
& DT
Hold down learn switch & insert battery.
SmartKey
Power on
Micro Contact
Hold down button
Access the Learn Menu using the Omit “Hot” key
From any top level engineering menu pressing the
/
O
key
will take you to the
Ricochet
learn menu above.
Menu
/
O
Ricochet Learn Menu
YES to Select:-
????????????????
/
O
YES to Select:-
Learn Ricochet
IMPORTANT
In all cases when entering the Learn menu the next available free
Zone will be chosen to learn a device too. It will not be possible to
learn a device to a Zone that already has a device learned too it. The
number of expander’s on the system will dictate which next “free”
zone is chosen to learn too.
When all device slots have been used the following screen will be
shown
All Devices
Learnt!
Pressing the
N
/
N
key will return you to the
Ricochet
learn menu; pressing the
/
R
key will enter the Delete
devices menu.
Commissioning
IMPORTANT
Once all devices are learnt they should be installed in their
locations starting closest to the expander and working to
furthest away. To start commission mode the receiver should be
in Tamper, or in the case of the -W panels place the jumper on
“Fit for Commission” position.
Wait for at least 15 minutes and the test all devices.
Auto Zone Type & Area
When learning devices, if no editing has taken place of the control
panel onboard hardwired zones, these will be switched to Not Used
after the first
Ricochet
device is learned to the system; the following
defaults will be used for
Ricochet
devices learned to the system.
Zone
Type
Area
001-008
Not Used
N/A
009
Entry/Exit 1
A
010
Guard Access
A
011 & above
Guard
A
IMPORTANT
If any editing of any of the on board control panel zones is carried
out
BEFORE
any
Ricochet
devices are learned too the system, the
control panel zones will remain at factory defaults.
Deleting Devices
Delete Devices
To delete devices from the system, access the
Ricochet
Learn
menu. Any of the methods previously detailed may be used.
The
/
R
key is used to access the Delete option.