INS467-9 27/47
N
/
N
then
9
.
Enter
18
to select the Assign Radio Device menu, if an error tone is
2.
generated then the receiver is not installed or configured correctly.
Enter the two digit zone number that you want to assign the detector to e.g.,
3.
01
*
.
Press the learn switch or short the learn pins and insert the battery. The
4.
panel will generate an acceptance tone and the detector is now assigned to
the selected zone.
Program the zone type and attributes as required. Note: The Zone Wiring
5.
must be programmed as "Double EOL", if a tamper response is required from
the detector.
Repeat steps 2 - 5 for other detectors.
6.
*When using a Premier Elite 8XP-W devices can only assigned to Zones 1-8 when
learning. Using Wintex the learned Zones can be changed to any that are
available.
Removing Detectors
If a detector is no longer required it must be unassigned from the system. To
remove a detector from a zone, proceed as follows:
Select engineer’s mode by entering the engineer code followed by
1.
N
/
N
then
9
.