The 

Premier Elite 5Ci-W

 sounder is an Internal warning device with 

Ricochet

®

 mesh technology. It is now even easier to add an internal 

wireless sounder to your security system. As the device is self powered the only limit on the number of units you can put on  a system is 
determined by how many free 

Ricochet

 enabled zones you have available. 

 

This unit is NOT designed for external applications. 

Tamper Detection 

As this unit is designed for internal applications only, and may be mounted at low level and within easy reach the SAB facility  has been 
disabled and the unit 

WILL NOT

 self activate in the case of the device being tampered. 

System Compatibility 

The 

Premier  Elite  5Ci-W

  is  compatible  with  all 

Premier  Elite

  control  panels  V2.11  and  later,  and 

Premier  Elite  8XP-W

  & 

Premier  Elite 

32XP-W

Ricochet

 Monitor V2.18.2 or later should also be used. 

Battery Pack 

The battery pack is retained by a reusable cable tie. and should be secured through the holes in the backplate above the Piezo module. 

 

All  eight  batteries  (supplied)  must  be  installed  with  the  correct  polarity.  Failure  to  do  so  will  result  in  the  device  reporting  a 

battery  fault.  If  1-2  batteries  are  incorrectly  fitted  the  firmware  will  detect  this  on  power  up  and  flash  both  comfort  LED’s  for 

approximately 10 minutes. While the unit is in this state it will not learn to a panel. After approximately 10 minutes the unit will 
power off in order to save energy. 

PCB Layout 

 

Summary of Contents for Premier Elite 5Ci-W

Page 1: ...Premier Elite 5Ci W Installation Manual INS655 3 ...

Page 2: ...T self activate in the case of the device being tampered System Compatibility The Premier Elite 5Ci W is compatible with all Premier Elite control panels V2 11 and later and Premier Elite 8XP W Premier Elite 32XP W Ricochet Monitor V2 18 2 or later should also be used Battery Pack The battery pack is retained by a reusable cable tie and should be secured through the holes in the backplate above th...

Page 3: ...Learning the Sounder As with all Ricochet enabled devices the sounder should be learned to the control panel along with all other devices BEFORE it is installed in it s final location The Premier Elite 5Ci W is learned to a Zone on the control panel in the same way that Ricochet enabled detection devices are The Zone type and Ricochet Device Mode is automatically assigned based on the type of devi...

Page 4: ...activation on tamper will be re enabled within 2 minutes after which the LEDs will alternate slowly to signal normal operation If the tamper circuit is re opened within the 2 minute period then hold off mode will be restored The LED s will only flash after hold off mode has stopped IF the LED jumper is in the ON position The strobe is disabled during hold off mode Hold off mode is immediately canc...

Page 5: ...ironmental Protection N A Brightness 100mcd typical Flash Rate tamper secure 1 4 sec flash at 5 sec intervals alternating typical Wireless Frequency 868 0MHz 868 6MHz Operating Temperature 25 C 13 F to 55 C 131 F Storage Temperature 25 C 13 F to 60 C 140 F EMC Environment Residential Commercial Light Industrial Industrial The flash rate will reduce to 0 125Hz after flashing for 20 minutes 1 flash ...

Page 6: ...e in systems designed to comply with EN 50131 4 EN50131 5 3 and PD6662 at Grade 2 and Environmental Class II Security Grade 2 Environmental Class 2 EN Standard Premier Elite 5Ci W EN60950 1 EN61000 6 3 EN 301 489 3 EN50130 4 EN300 220 1 EN50131 1 EN50130 5 EN50131 5 3 EN50131 6 PD6662 EN50131 4 Warranty All Texecom products are designed for reliable trouble free operation Quality is carefully moni...

Page 7: ...Premier Elite 5Ci W Internal Installation Manual INS655 3 7 Notes ...

Page 8: ...shire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International Customers Tel 44 1706 233875 Email techsupport texe com Texecom Limited 2015 INS655 3 ...

Reviews: