RamSan-500 User’s Manual
17 of 48
4.4.3
4.4.3
4.4.3
4.4.3
Manual Restart
Manual Restart
Manual Restart
Manual Restart
The administrator can reboot the RamSan manually from the front
panel display. This procedure safely synchronizes all data in RAM to
the internal Flash module storage, powers off for around 5 seconds,
and then powers back on.
Main Menu
Manual Restart
To shut down the system using
the front panel, use the arrow
buttons to cycle through the
top-level menu to select
“
Manual Restart
”. Use the
Select
button to select this
menu item.
Restart System?
↓
Yes
↑
No
The display prompts you to
confirm that you wish to
“
Restart System
”.
To cancel
the shutdown, use the
↑
↑
↑
↑
button
to return to the main menu. To
proceed with the shutdown,
use the
↓
↓
↓
↓
button to confirm the
system power off.
Powering Off 90%
Now, the front panel display
indicates that the system is
powering off. When the
system is ready, it will
automatically shut off. In
approximately 5 seconds time,
the system will turn back on.
4.4.4
4.4.4
4.4.4
4.4.4
Automatic
Automatic
Automatic
Automatic S
S
S
Shutdown
hutdown
hutdown
hutdown
In the event that the system senses a high system temperature,
power out of range, or a variety of other dangerous environmental
conditions, the system will automatically initiate the shutdown
procedure.
4.5
Network Configuration with the Front Panel Display
The RamSan-500 allows system monitoring and configuration through the
installed Ethernet module. To access the system’s Ethernet port you will
need to provide the system with an IP address, subnet mask, and possibly
a gateway address. The administrator may assign the IP address in one of
three ways: Static IP, DHCP, or No Ethernet. The default factory setting is
DHCP.
For any questions regarding IP assignment values, please consult your
network administrator.