Texas Instruments UCC29950EVM-631 User Manual Download Page 37

SPACER

6.

Disclaimers:

6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY WRITTEN DESIGN MATERIALS PROVIDED WITH THE EVM (AND THE

DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL FAULTS." TI DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY
THIRD PARTY PATENTS, COPYRIGHTS, TRADE SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.

6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS AND

CONDITIONS SHALL BE CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY
OTHER INDUSTRIAL OR INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD
PARTY, TO USE THE EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY
INVENTION, DISCOVERY OR IMPROVEMENT MADE, CONCEIVED OR ACQUIRED PRIOR TO OR AFTER DELIVERY OF
THE EVM.

7.

USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS.

USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS

LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS AND CONDITIONS. THIS OBLIGATION
SHALL APPLY WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY
OTHER LEGAL THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.

8.

Limitations on Damages and Liability:

8.1

General Limitations

. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,

INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS ANDCONDITIONS OR THE USE OF THE EVMS PROVIDED HEREUNDER, REGARDLESS OF WHETHER TI HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED
TO, COST OF REMOVAL OR REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES, RETESTING, OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS,
LOSS OF SAVINGS, LOSS OF USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL
BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED.

8.2

Specific Limitations.

IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY WARRANTY OR OTHER OBLIGATION

ARISING OUT OF OR IN CONNECTION WITH THESE TERMS AND CONDITIONS, OR ANY USE OF ANY TI EVM
PROVIDED HEREUNDER, EXCEED THE TOTAL AMOUNT PAID TO TI FOR THE PARTICULAR UNITS SOLD UNDER
THESE TERMS AND CONDITIONS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE CLAIMED. THE EXISTENCE
OF MORE THAN ONE CLAIM AGAINST THE PARTICULAR UNITS SOLD TO USER UNDER THESE TERMS AND
CONDITIONS SHALL NOT ENLARGE OR EXTEND THIS LIMIT.

9.

Return Policy.

Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)

will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.

10.

Governing Law:

These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,

without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2015, Texas Instruments Incorporated

spacer

Summary of Contents for UCC29950EVM-631

Page 1: ...Using the UCC29950EVM 631 User s Guide Literature Number SLUUB69A March 2015 Revised March 2015 ...

Page 2: ...This EVM makes use of the device features to control a two stage power supply that is rated for 300 W output power An overload timer tracks the extent and duration of overload and trips the overload protection when the current exceeds the over current protection profile described in the datasheet The overload protection turns the power stages off and then attempts restarts at 1 second intervals If...

Page 3: ...lf Bias or Aux Bias Modes CAUTION High voltage levels are present on the evaluation module whenever it is energized Proper precautions must be taken when working with the EVM The large bulk capacitor C6 and the output capacitors C17 C20 C21 C22 C23 C24 C20 and C12 must be completely discharged before the EVM can be handled Serious injury can occur if proper safety precautions are not followed 2 2 ...

Page 4: ...IN min VIN VIN max VOUT line Line regulation 0 1 IOUT IOUT max VIN 115 VAC fLINE 60 Hz 0 1 IOUT min IOUT IOUT max VOUT load Load regulation VIN 230 VAC fLINE 50 Hz 0 1 IOUT min IOUT IOUT max VIN min VIN VIN max IOUT Output load current 0 25 A fLINE min fLINE fLINE max VIN min VIN VIN max POUT Output power 0 300 W fLINE min fLINE fLINE max VIN 115 VAC High frequency output voltage ripple fLINE 60 H...

Page 5: ...OUT IOUT max THD Total harmonic distortion VIN 230 VAC fLINE 50 Hz 6 10 IOUT IOUT max fSW LLC LLC stage switching frequency 70 110 350 kHz VIN 115 VAC fLINE 60 Hz 88 3 IOUT IOUT max ηFL Full load efficiency VIN 230 VAC fLINE 50 Hz 90 5 IOUT IOUT max VIN 115 VAC fLINE 60 Hz 87 8 IOUT IOUT max ηAV Average efficiency VIN 230 VAC fLINE 50 Hz 90 2 IOUT IOUT max tAMB Ambient temperature 25 C 5 SLUUB69A ...

Page 6: ...AGND 3 09Meg R39 3 09Meg R40 3 09Meg R38 100k R47 100k R54 AGND PSON TP16 TP17 TP12 TP13 TP15 VCC VCC BULK AC1 AC2 PFCCS LLC_RCS FB GD1 0 R35 TP14 PFCGD GD2 4 6 3 1 S1 4 6 3 1 S2 100pF C46 AGND R61 1 00k TP11 0 R19 GD2 2 VCC 3 SUFG 4 SUFS 5 AGND 6 MD_SEL PS_ON 7 VBULK 8 AC2 9 AC1 10 LLC_CS 11 FB 12 PFC_CS 13 GD1 14 AC_DET 15 PFC_GD 16 GND 1 U6 UCC29950D 375Vdc Schematic www ti com 4 Schematic Figu...

Page 7: ...LK RTN 1 F μ C16 NT1 Net Tie AGND VOUT VOUT TP6 TP7 10K R33 VCC VCC VCC OUTPUT 12 VDC 25 A VOUT VOUT RTN NOMINAL VBULK 390VDC AC1 AC2 PFCCS PFCGD GD2 GD1 FB VCC LLC_RCS BULK PGND 1 00 R57 2 2 R58 L2 1 2 3 4 J3 1 2 3 J2 1 2 3 5 6 13 14 15 16 17 18 19 20 T1 TP19 TP27 TP24 TP21 TP26 TP18 TP23 TP20 TP22 TP28 1 2 3 HS1 1 2 3 HS2 1 2 3 HS3 PGND TP25 TP29 TP30 TP31 TP32 TP33 10 0M R14 1 10M R15 AGND 10μF...

Page 8: ...acitor C6 may be monitored at J2 as shown or at TP31 pos and TP 32 neg Test Setup www ti com 5 Test Setup Figure 3 shows the test setup recommended in order to evaluate the UCC29950EVM 631 in Self Bias Mode Figure 4 shows the test setup recommended in order to evaluate the UCC29950EVM 631 in Aux Bias Mode Figure 3 UCC29950EVM 631 Recommended Self Bias Test Set Up 8 Using the UCC29950EVM 631 300 W ...

Page 9: ...ltage on the bulk capacitor C6 may be monitored at J2 as shown or at TP31 pos and TP 32 neg www ti com Test Setup Figure 4 UCC29950EVM 631 Recommended Aux Bias Test Set Up WARNING High voltages that may cause injury exist on this evaluation module EVM Please ensure all safety procedures are followed when working on this EVM Never leave a powered EVM unattended 9 SLUUB69A March 2015 Revised March 2...

Page 10: ... a digital voltmeter V1 directly across TP18 and TP27 with the positive terminal at TP18 and the negative terminal at TP27 A dc current meter A1 should be placed in series with the electronic load for accurate output current measurements Oscilloscope A digital or analog oscilloscope with 500 MHz scope probes is recommended Fan A fan capable of 200 LFM to 400 LFM should be used to maintain componen...

Page 11: ...TP15 PSON MD_SEL PS_ON signal TP16 LLC_CS LLC stage current sense input signal TP17 FB LLC stage feedback signal TP18 TP18 LLC stage split capacitor TP19 VOUT EVM positive output TP20 TP20 LLC transformer output TP21 VDD VDD supply to MOSFET driver devices TP22 TP20 LLC transformer output TP23 TP23 LLC stage rectified output TP24 TP24 LLC stage low side MOSFET gate TP25 TP25 LLC stage high side MO...

Page 12: ...atic smock and safety glasses should also be worn Because voltages in excess of 400 V may be present on the EVM do not connect the ground strap from the smock to the bench If testing with a load set the electronic load to Constant Current Mode 2 Power Up in Self Bias Mode a Connect the equipment as shown in Figure 3 b Set the electronic load to 2 A c S1 to the off position switch toggle pointed to...

Page 13: ...tings for PFC and LLC on Aux Bias Mode and Self Bias Mode Figure 8 S1 and S2 Settings for PFC Stage On LLC Stage Off Aux Bias Mode only 13 SLUUB69A March 2015 Revised March 2015 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module Submit Documentation Feedback Copyright 2015 Texas Instruments Incorporated ...

Page 14: ...ench If testing with a load set the electronic load to Constant Current Mode 2 Power Up in Aux Bias Mode a Connect the equipment as shown in Figure 4 b Set the electronic load to 2 A c Set the two switches S1 and S2 to the off position switch toggle pointed to the heatsink as shown in Figure 6 d Check that the link connects pin 1 to pin 2 of J4 e Turn on the 13 V bias supply f Set S2 to the on pos...

Page 15: ... 2 Vary the AC source from 90 VAC to 264 VAC 3 Observe that the output voltage on DMM V1 stays within 0 1 of the output voltage regulation value 6 4 Power Factor The power meter may be used to monitor the power factor PF of the line current and the input power taken by the EVM The PF is very close to 1 0 under most operating conditions At very light loads where the EVM enters a burst mode of opera...

Page 16: ...Set the electronic load to apply an overload load transient 25 A to 33 A to 25 A for a short period 20 ms This will not trip the over current protection Increase the time period incrementally until the OCP1 over current protection is activated The second OCP level OCP2 operates at about 42 A after 10 ms This should be observed in the same way as the OCP1 Set the load to apply an overload load tran...

Page 17: ...by observing the voltage across the X Capacitor when the line is disconnected NOTE Turning the output off on most AC sources sets the source to 0 V It is best to use a mechanical switch or relay to disconnect the line voltage from the EVM Alternatively wire a suitably rated line socket and plug into the line cord and use that to disconnect the EVM Put a differential scope probe from TP1 to TP4 The...

Page 18: ...ted digitally thus eliminating the need for external compensation components The Bode Plots below were taken from a typical EVM and show a loop crossover frequency of 9Hz with a phase margin of greater than 60 Figure 9 PFC Loop Gain Phase at 300 W 115 V Figure 10 PFC Loop Gain Phase at 300 W 230 V 7 2 LLC Stage Loop Stability The gain and phase characteristic of the LLC stage is dominated by the e...

Page 19: ... a function of line voltage and current The UCC29950EVM 631 also meets the requirements of 80PLUS Silver with good margin and is close to meeting the requirements of 80PLUS Gold Table 3 UCC29950EVM 631 Typical Average Efficiency VIN V F Hz LOAD PIN W POUT W EFFICIENCY PF AVG EFF 115 60 100 345 3 300 0 86 9 0 999 88 0 75 256 7 225 0 87 6 0 999 50 168 0 150 0 89 2 0 997 25 84 95 75 0 88 3 0 990 230 ...

Page 20: ...7 5 30 D001 90 V 115 V 230 V Performance Data and Typical Characteristic Curves www ti com 7 4 Total Harmonic Distortion Figure 14 UCC29950EVM 631 Total Harmonic Distortion as a function of line voltage and load current 7 5 Current Harmonics Figure 15 UCC29950EVM 631 Current Harmonics 230 VAC 50 Hz input full load 20 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module SLUUB69A March 2015 R...

Page 21: ...035 12 04 12 045 12 05 12 055 12 06 12 065 12 07 12 075 12 08 12 085 12 09 D001 230 V 115 V www ti com Performance Data and Typical Characteristic Curves 7 6 Line Load Regulation Figure 16 Line Regulation vs Input Voltage Figure 17 Load Regulation vs Output Current 7 7 Power Factor Figure 18 Power Factor vs Input Power 21 SLUUB69A March 2015 Revised March 2015 Using the UCC29950EVM 631 300 W PFC L...

Page 22: ...950EVM 631 Input Current 90 VAC 60 Hz full load 2 A div 115 VAC 60 Hz full load 2 A div Figure 21 UCC29950EVM 631 Input Current 230 VAC 50 Hz full load 1 A div 22 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module SLUUB69A March 2015 Revised March 2015 Submit Documentation Feedback Copyright 2015 Texas Instruments Incorporated ...

Page 23: ...ple 115 VAC 60 Hz input full load 230 VAC 50 Hz input full load Figure 24 UCC29950EVM 631 Output Noise Figure 25 UCC29950EVM 631 Output Noise 115 VAC 60 Hz input full load 230 VAC 50 Hz input full load 23 SLUUB69A March 2015 Revised March 2015 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module Submit Documentation Feedback Copyright 2015 Texas Instruments Incorporated ...

Page 24: ...r intervals during which no energy transfer occurs This allows the controller to maintain the correct average output voltage at the expense of an increase in output ripple Typical output ripple performance is shown in Figure 26 and Figure 27 below The burst interval and the output ripple amplitude depends on whether the EVM is operating in Aux Bias or Self Bias Mode Figure 26 VOUT No Load Aux Bias...

Page 25: ...ure 28 DC Coupled VOUT 0 A Aux Bias Burst is Figure 29 VOUT 1 A Aux Bias Approximately 8 ms Long Burst Rep Interval is Approximately 340 ms Figure 30 VOUT 25 A Aux Bias Figure 31 VOUT 25 A Aux Bias 25 SLUUB69A March 2015 Revised March 2015 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module Submit Documentation Feedback Copyright 2015 Texas Instruments Incorporated ...

Page 26: ...VAC Self Bias 390 mW 230 VAC Self Bias 660 mW 264 VAC Self Bias 745 mW 90 VAC Aux Bias 130 mW 254 mW 130 mW 384 mW 115 VAC Aux Bias 130 mW 200 mW 130 mW 330 mW 230 VAC Aux Bias 130 mW 160 mW 130 mW 290 mW 264 VAC Aux Bias 130 mW 175 mW 130 mW 305 mW 26 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module SLUUB69A March 2015 Revised March 2015 Submit Documentation Feedback Copyright 2015 Tex...

Page 27: ...9950EVM 631 printed circuit board Figure 34 UCC29950EVM 631 Top Layer Assembly Drawing top view Figure 35 UCC29950EVM 631 Bottom Layer Assembly Drawing bottom view 27 SLUUB69A March 2015 Revised March 2015 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module Submit Documentation Feedback Copyright 2015 Texas Instruments Incorporated ...

Page 28: ...29950EVM 631 Top Copper top view Figure 37 UCC29950EVM 631 Bottom Copper bottom view 28 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module SLUUB69A March 2015 Revised March 2015 Submit Documentation Feedback Copyright 2015 Texas Instruments Incorporated ...

Page 29: ...awing and PCB Layout Figure 38 Components Assembly 29 SLUUB69A March 2015 Revised March 2015 Using the UCC29950EVM 631 300 W PFC LLC Off Line PSU Module Submit Documentation Feedback Copyright 2015 Texas Instruments Incorporated ...

Page 30: ...mic 1 µF 35 V 10 X7R 0805 Taiyo Yuden GMK212B7105KG T Capacitor aluminum 220 µF 35 V 20 0 087 Ω 1 C26 Nippon Chemi Con EKY 350ELL221MH15D TH 1 C29 Capacitor ceramic 0 047 µF 50 V 10 X7R 0805 AVX 08055C473KAT2A 2 C33 C39 Capacitor ceramic 0 1 µF 50 V 10 X7R 0603 AVX 06035C104KAT2A 2 C34 C35 Capacitor ceramic 10 µF 35 V 10 X7R 1206 Taiyo Yuden GMK316AB7106KL 3 C36 C37 C38 Capacitor ceramic 470 pF 50...

Page 31: ...J2 Terminal block 5 08 mm vertical 3 position th ED120 3DS Technology On Shore 1 J3 Terminal block 4 x 1 5 08 mm TH ED120 4DS Technology Header TH 100 mil 1 x 3 gold plated 230 mil above Sullins Connector 1 J4 PBC03SAAN insulator Solutions On Shore 1 J5 Terminal block 5 08mm vertical 2 position th ED120 2DS Technology 1 J6 Header shrouded 100 mil 5 x 2 gold TH TE Connectivity 5103308 1 Wurth Elekt...

Page 32: ...Ω 1 0 1 W 0603 Vishay Dale CRCW0603100KFKEA 2 R52 R53 Resistor 470 Ω 1 0 1 W 0603 Yageo America RC0603FR 07470RL 1 R55 Resistor 2 21 kΩ 1 0 1 W 0603 Vishay Dale CRCW06032K21FKEA 1 R56 Resistor 3 32 kΩ 1 0 1 W 0603 Vishay Dale CRCW06033K32FKEA 1 R57 Resistor 1 00 Ω 1 0 125 W 0805 Panasonic ERJ 6RQF1R0V 1 R58 Resistor 2 2 Ω 5 0 125 W 0805 Vishay Dale CRCW08052R20JNEA 1 R60 Resistor 0 Ω 5 0 25 W 1206...

Page 33: ...w Side Gate 1 U1 TI UCC27511DBV Drivers 1 U2 High Speed Low Side Gate Driver Device D0014A Texas Instruments UCC27714D14 1 U5 Precision Programmable Reference DBZ0003A Texas Instruments TL431AIDBZ Continuous Conduction Mode Power Factor Correction 1 U6 and LLC Resonant Converter Combo Controller Texas Instruments UCC29950D D0016A Single Output LDO 100 mA Adjustable 1 2 to 18 5 V Output 3 to 60 V I...

Page 34: ...ring the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repair such EVM or provide replacements Repaired EVMs shall be warranted for the remainder of the original warranty period Replaced EVMs shall be warranted for a new full ninety 90 day warranty period 3 ...

Page 35: ... by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Concernant les EVMs avec antennes détachables Conformément à la rég...

Page 36: ... connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the inputs and outputs kept within the specified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors cu...

Page 37: ...F REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE LOSS OF DATA OR BUSINESS INTERRUPTION NO CLAIM SUIT OR ACTION SHALL BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED 8 2 Specific Limitations IN NO EVENT SHALL T...

Page 38: ...esponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failur...

Reviews: