Load Current (A)
Ef
ficie
nc
y
(%)
0
2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
80
81
82
83
84
85
86
87
88
89
90
91
D001
115 V
90 V
230 V
Load Current (A)
Ef
ficie
nc
y
(%)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
D001
90 V
115 V
230 V
Performance Data and Typical Characteristic Curves
7.3
Efficiency
Figure 12. UCC29950EVM-631 Typical Efficiency
Figure 13. UCC29950EVM-631 Typical Light-Load
(as a function of line voltage and current)
Efficiency
(as a function of line voltage and current)
The UCC29950EVM-631 also meets the requirements of 80PLUS Silver with good margin and is close to
meeting the requirements of 80PLUS Gold.
Table 3. UCC29950EVM-631, Typical Average Efficiency
V
IN
(V)
F (Hz)
% LOAD
P
IN
(W)
P
OUT
(W)
EFFICIENCY
PF
AVG EFF (%)
(%)
115
60
100
345.3
300.0
86.9
0.999
88.0
75
256.7
225.0
87.6
0.999
50
168.0
150.0
89.2
0.997
25
84.95
75.0
88.3
0.990
230
50
100
337.0
300.0
89.0
0.995
90.1
75
250.7
225.0
89.7
0.990
50
164.4
150.0
91.3
0.982
25
83.02
75.0
90.3
0.958
19
SLUUB69A – March 2015 – Revised March 2015
Using the UCC29950EVM-631 300-W PFC/LLC Off-Line PSU Module
Copyright © 2015, Texas Instruments Incorporated