0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
AMPLITUDE (A)
HARMONIC NUMBER
CURRENT HARMONICS, 230V
AC
, 50 Hz, FULL LOAD
PWR631
IEC61000-3-2 Class D max
Input Power (W)
THD (%)
30
60
90
120 150 180 210 240 270 300 330 360
2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
D001
90 V
115 V
230 V
Performance Data and Typical Characteristic Curves
7.4
Total Harmonic Distortion
Figure 14. UCC29950EVM-631 Total Harmonic Distortion
(as a function of line voltage and load current)
7.5
Current Harmonics
Figure 15. UCC29950EVM-631 Current Harmonics
(230-V
AC
, 50-Hz input, full load)
20
Using the UCC29950EVM-631 300-W PFC/LLC Off-Line PSU Module
SLUUB69A – March 2015 – Revised March 2015
Copyright © 2015, Texas Instruments Incorporated