6.4 GUI Devices Window
The device command window will not do any reads of the device until the
En 520 No WD
button has been
selected and the watch dog timer has been disabled, see
.
Figure 6-13. Device Command Window
Once the
En 520 No WD
has been selected, the GUI will perform an initial read of all the registers and load the
information into the device command window, shown in
SHORT
,
BSTUV
, and
STATUS
are flagged red because those faults conditions have occurred. The
SHORT
fault condition occurs because the
output is off and no current is driving the LEDs and the voltage at the output is less than 2.45 V on the CSP pin,
which indicates a
SHORT
condition.
BSTUV
fault indicates that the bootstrap supply is lower than 2.95 V, which
is correct because the booststrap voltage is created when the output is turned on and the switch node is pulled
to ground to charge the booststrap capacitor to drive the high-side FET.
STATUS
fault indicates that a fault has
occurred and is the logic OR of the fault bits for that channel.
TPS92520EVM-133 Power UP and Operation
42
TPS92520EVM-133 Dual 1.6-A Synchronous Buck LED Driver Evaluation
Module
SLUUCC4 – OCTOBER 2020