3.13.3 Video Capture Channel x Field 1 Start Register (VCxSTRT1)
Video Capture Registers
Table 3-15. Video Capture Channel A Control Register (VCACTL) Field Descriptions (continued)
Description
Bit
field
(1)
symval
(1)
Value
BT.656 or Y/C Mode
Raw Data Mode
TCI Mode
7
CON
(2)
OF(value)
Continuous capture enable bit.
DEFAULT
0
Continuous capture is disabled.
DISABLE
ENABLE
1
Continuous capture is enabled.
6
FRAME
(2)
OF(value)
Capture frame (data) bit.
DEFAULT
0
Do not capture frame.
Do not capture single
Do not capture single
data block.
packet.
NONE
FRMCAP
1
Capture frame.
Capture single data
Capture single packet.
block.
5
CF2
(2)
OF(value)
Capture field 2 bit.
NONE
0
Do not capture field 2.
Do not capture field 2.
Not used.
DEFAULT
1
Capture field 2.
Capture field 2.
Not used.
FLDCAP
4
CF1
(2)
OF(value)
Capture field 1 bit.
NONE
0
Do not capture field 1.
Do not capture field 1.
Not used.
DEFAULT
1
Capture field 1.
Capture field 1.
Not used.
FLDCAP
3
Reserved
-
0
Reserved. The reserved bit location is always read as 0. A value written to this
field has no effect.
2-0
CMODE
OF(value)
0-7h
Capture mode select bit.
DEFAULT
0
Enables 8-bit BT.656 mode.
Not used.
BT656B
RAWB
2h
Enables 8-bit raw data mode.
8-bit TCI mode.
YCB
4h
Enables 16-bit Y/C mode.
Not used.
RAW16
6h
Enables 16-bit raw mode.
Not used.
(2)
For complete encoding of these bits, see
, and
The captured image is a subset of the incoming image. The video capture channel x field 1 start register
(VCASTRT1, VCBSTRT1) defines the start of the field 1 captured image. Note that the size is defined
relative to incoming data (before scaling).
In BT.656 or Y/C modes, the horizontal (pixel) counter is reset (to 0) by the horizontal event (as selected
by the HRST bit in VCxCTL) and the vertical (line) counter is reset (to 1) by the vertical event (as selected
by the VRST bit in VCxCTL). Field 1 capture starts when HCOUNT = VCXSTART, VCOUNT =
VCYSTART, and field 1 capture is enabled.
In raw capture mode, the VCVBLNKP bits defines the minimum vertical blanking period. If CAPEN stays
de-asserted longer than VCVBLNKP clocks, then a vertical blanking interval is considered to have
occurred. If the SSE bit is set when the capture first begins (the VCEN bit is set in VCxCTL), the capture
does not start until two intervals are counted. This allows the video port to synchronize its capture to the
top of a frame when first started.
In TCI capture mode, the capture starts when the CAPEN signal is asserted, the FRMC bit (in VCxSTAT)
is cleared, and a SYNC byte is detected.
The video capture channel x field 1 start register (VCxSTRT1) is shown in
and described in
.
SPRUEM1 – May 2007
Video Capture Port