7.2.2 Power SmartRF TrxEB from external power source
Connect the power from the external power source to the external power source connector on
SmartRF TrxEB and set the power source selection jumpers accordingly. Please see section
6.3.3 for a detailed description on how to power the SmartRF TrxEB from an external power
source.
7.3 Connect signals
7.3.1 Common signals
Table 12 shows the common signals needed to communicate with transceivers on a mounted EM
board. Figure 20 shows where the signals listed Table 12 and Table 13 can be found on the P7
EM I/O breakout header on SmartRF TrxEB.
TrxEB Signal Name TrxEB breakout pin Description
RF_RESET_N
P7.10
Signal used to reset EM board
RF_SPI0_SCLK
P7.12
EM SPI interface clock signal
RF_SPI0_CS_N
P7.14
EM SPI interface chip select signal, active low
RF_SPI0_MOSI
P7.16
EM SPI interface MOSI signal
RF_SPI0_MISO
P7.18
EM SPI interface MISO signal
GND
P7.20
Common ground for EB and external MCU board
Table 12
– Strapping overview to connect common signals to an external MCU
NOTE:
When powering the SmartRF TrxEB from an external power source, the TrxEB main
power switch must be in on position for the EB to be powered up.
Summary of Contents for SWRU294
Page 1: ...SWRU294 SmartRF Transceiver Evaluation Board User s Guide ...
Page 2: ......
Page 41: ...SWRU294 Appendix A Schematics SmartRF TrxEB 1 3 0 ...
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ...SWRU294 Appendix B Schematics SmartRF TrxEB 1 5 0 ...
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......