November 4, 2009
27
Parameters
Table A-1 provides a summary of all configuration parameters. See “Parameter Descriptions” on
page 27 for more information.
Parameter Descriptions
This section describes parameter configuration in detail. The parameters are grouped into two
areas: Motor Running Configuration parameters and Motor Drive Configuration parameters.
Table A-1. Parameter Configuration Summary
Parameter Name
ID
Units
Range
Default
See
Motor Running Configuration Parameters
PARAM_TARGET_POS
whole
steps
-8388608–8388607
0
PARAM_MAX_CURRENT
mA
1000–10000
4000
PARAM_TARGET_SPEED
steps/sec
10–10000
200
PARAM_ACCEL
steps/sec
2
100–60000
30000
PARAM_DECEL
steps/sec
2
100–60000
60000
Motor Drive Configuration Parameters
PARAM_RESISTANCE
m
Ω
100–5000
750
PARAM_PWM_FREQUENCY
Hz
16000–32000
20000
PARAM_FIXED_ON_TIME
μ
S
1–10000
800
PARAM_DRIVE_CURRENT
mA
100–3000
1500
PARAM_HOLDING_CURRENT
mA
0–3000
0
PARAM_CONTROL_MODE
choice
Chopper,
Open-loop or
Closed-loop PWM
Chopper
PARAM_DECAY_MODE
choice
Fast or Slow
Slow
PARAM_STEP_MODE
choice
Full, Half, Micro, or
Wave
Half
PARAM_BLANK_OFF
μ
S
20–10000
100