Control Registers
302
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
F021 Flash Module Controller (FMC)
5.7.40 EEPROM Emulation Error Status Register (EE_STATUS)
During emulation mode, this address is frozen even when read. By setting the SUSP_IGNR bit in
FEDACCTRL1 register, (see
) this register can be unfrozen in emulation mode.
This register is not changed with the reset signal and contains unknown data at power-up.
All these error status bits can be deactivated by writing a 1 to the bit. Writing a 0 has no effect.
Bits 0 to 3 show correctable errors while bits 4 to 12 show uncorrectable errors. When the uncorrectable
errors are triggered, the current address is stored in the EE_UNC_ERR_ADD register.
These error bits are not set while the FMC is in the suspend mode but they can be cleared in suspend by
writing 1s to the bits. By setting the SUSP_IGNR bit to 1, these error bits can be set in suspend mode
(see
Figure 5-47. EEPROM Emulation Error Status Register (EE_STATUS) [offset = 31Ch]
31
24
Reserved
R-0
23
16
Reserved
R-0
15
13
12
11
9
8
Reserved
EE_D_UNC_
ERR
Reserved
EE_UNC_
ERR
R-0
RCP-u
R-0
RCP-u
7
6
5
4
3
2
1
0
Reserved
EE_CMG
Reserved
EE_CME
EE_D_COR_
ERR
EE_ERR_
ONE_FLG
EE_ERR_
ZERO_FLG
EE_ERR_
PRF_FLG
R-0
R-0
R-0
R-0
RCP-u
RCP-u
RCP-u
RCP-u
LEGEND: R = Read only; RCP = Read and Clear in Privilege Mode; -
n
= value after reset; -u = unchanged value on internal reset, cleared
on power up
Table 5-52. EEPROM Emulation Error Status Register (EE_STATUS) Field Descriptions
Bit
Field
Value
Description
31-13
Reserved
0
Reads return 0. Writes have no effect.
12
EE_D_UNC_ERR
Diagnostic Mode Uncorrectable Error Status Flag
0
No uncorrectable error was detected in diagnostic mode 1.
1
An uncorrectable error was detected in diagnostic mode 1. This means two or more bits in
the data or ECC field have been found in error, or one or more bits in the address have
been found in error.
11-9
Reserved
0
Reads return 0. Writes have no effect.
8
EE_UNC_ERR
EEPROM Emulation Uncorrectable Error Flag
0
No uncorrectable errors were detected in bank 7.
1
An uncorrectable error was detected in bank 7.
7
Reserved
0
Reads return 0. Writes have no effect.
6
EE_CMG
EEPROM Emulation Compare Malfunction Good
0
Compare malfunction was detected on the Bus2 SECDED logic.
1
Compare malfunction was not detected on the Bus2 SECDED logic.
5
Reserved
0
Reads return 0. Writes have no effect.
4
EE_CME
EEPROM Emulation Compare Malfunction Error
0
Compare malfunction was not detected on the Bus2 SECDED logic.
1
Compare malfunction was detected on the Bus2 SECDED logic.