SLOU TI Information – Selective Disclosure
10
PurePath™ Smart Amp User Manual (TAS5766M/68M)
1.6.2 Miscellaneous Equipment
In order to perform a full characterization the following hardware is recommended. Some of
these items are not needed if loudspeaker parameters are known.
Table 2.
Miscellaneous Equipment
Equipment
Description
Weight Scale
20g in 1mg increments preferred. The
Gemini-20 Portable Milligram Scale
by
is recommended. Not required if the force factor Bl is
provided by the speaker manufacturer.
Adhesive Putty
Removable Adhesive Putty
by
. Not required
if the force factor Bl is provided by the speaker manufacturer.
Metric Ruler
Size depends on loudspeaker diaphragm area (S
d
). Also used to
measure port area (S
p
). Plastic is preferred to prevent the magnet from
pulling the ruler. Not required if S
d
and S
p
parameters are known.
24V Power Supply A lab power supply capable of providing peak power to the speakers. A
24V, 6A supply addresses most circumstances. An external AC/DC
supply could be used as well, such as the
MENB1100A2403F01
by
A microphone is required for
Smart SPL
and characterizing
passive radiator
systems. Below is a
list of microphones that have been tested for Smart Amp.
Table 3.
Microphones Tested for Smart SPL and Passive Radiator Systems
Model
Manufacturer
Type
Mic: CME-1538-100LB
CUI, Inc.
Electret Condenser
(requires external 1.8V bias)
Capsule: 4938
Preamp: Type 2670
Brüel & Kjær
¼” Diameter Pressure Field
Mic: EMM-6
Dayton Audio
½” Diameter Condenser
(tested with Shure X2u USB Preamp)
Mic: iMM-6
Dayton Audio
Condenser
(requires external 1.8V bias)