Public Version
General-Purpose Interface Register Manual
www.ti.com
Table 25-47. GPIO_DEBOUNCINGTIME
Address Offset
0x054
Physical Address
0x4831 0054
Instance
GPIO1
0x4905 0054
GPIO2
0x4905 2054
GPIO3
0x4905 4054
GPIO4
0x4905 6054
GPIO5
0x4905 8054
GPIO6
Description
This register controls debouncing time (the value is global for all ports).
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
DEBOUNCEVAL
Bits
Field Name
Description
Type
Reset
31:8
RESERVED
Read returns 0
RW
0x000000
7:0
DEBOUNCEVAL
Input Debouncing Value in 31 microsecond steps.
RW
0x00
debouncing time = (DEBO1) x 31
m
s
Table 25-48. Register Call Summary for Register GPIO_DEBOUNCINGTIME
General-Purpose Interface Integration
•
System Power Management and Wake-Up
General-Purpose Interface Functional Description
•
Synchronous Path: Interrupt Request Generation
General-Purpose Interface Basic Programming Model
•
General-Purpose Interface Register Manual
•
General-Purpose Interface Register Mapping Summary
[7] [8] [9] [10] [11] [12] [13]
Table 25-49. GPIO_CLEARIRQENABLE1
Address Offset
0x060
Physical Address
0x4831 0060
Instance
GPIO1
0x4905 0060
GPIO2
0x4905 2060
GPIO3
0x4905 4060
GPIO4
0x4905 6060
GPIO5
0x4905 8060
GPIO6
Description
Clear to 0 the corresponding bits in the
register
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
CLEARIRQEN1
Bits
Field Name
Description
Type
Reset
31:0
CLEARIRQEN1
Clear Interrupt Enable 1
RW
0x00000000
0x0: No effect
0x1: Clear the corresponding bit in the
register
3502
General-Purpose Interface
SWPU177N – December 2009 – Revised November 2010
Copyright © 2009–2010, Texas Instruments Incorporated