Public Version
SCM Register Manual
www.ti.com
Bits
Field Name
Description
Type
Reset
4:0
OBSMUX8
Select the set of signals to be observed for hw_dbg8
See
0x00
Table 13-272. Register Call Summary for Register CONTROL_WKUP_DEBOBS_2
SCM Functional Description
•
•
:
SCM Register Manual
•
:
Table 13-273. Type Value For CONTROL_WKUP_DEBOBS_2 Register
[31] WKUPOBSERVABILITYDISABLE bit
0
1
OBSMUX11
RW
R
OBSMUX10
RW
R
OBSMUX9
RW
R
OBSMUX8
RW
R
Table 13-274. CONTROL_WKUP_DEBOBS_3
Address Offset
0x0000 0018
Physical Address
0x4800 2A74
Instance
GENERAL_WKUP
Description
Select the WKUP domain set of signals to be observed for hw_dbg15 hw_dbg14, hw_dbg13,
hw_dbg12
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
OBSMUX15
OBSMUX14
OBSMUX13
OBSMUX12
RESERVED
RESERVED
RESERVED
RESERVED
Bits
Field Name
Description
Type
Reset
31:29
RESERVED
Read returns reset value.
R
0x0
28:24
OBSMUX15
Select the set of signals to be observed for hw_dbg15
See
0x00
23:21
RESERVED
Read returns reset value.
R
0x0
20:16
OBSMUX14
Select the set of signals to be observed for hw_dbg14
See
0x00
15:13
RESERVED
Read returns reset value.
R
0x0
12:8
OBSMUX13
Select the set of signals to be observed for hw_dbg13
See
0x00
7:5
RESERVED
Read returns reset value.
R
0x0
4:0
OBSMUX12
Select the set of signals to be observed for hw_dbg12
See
0x00
Table 13-275. Register Call Summary for Register CONTROL_WKUP_DEBOBS_3
SCM Functional Description
•
•
:
SCM Register Manual
•
:
2638System Control Module
SWPU177N – December 2009 – Revised November 2010