Public Version
Display Subsystem Register Manual
www.ti.com
Table 7-263. Register Call Summary for Register RFBI_READ
Display Subsystem Basic Programming Model
•
:
•
Display Subsystem Register Manual
•
•
:
Table 7-264. RFBI_STATUS
Address Offset
0x5C
Physical address
0x4805 085C
Instance
RFBI
Description
The control register configures the RFBI status.
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Reserved
STATUS
Bits
Field Name
Description
Type
Reset
31:16
Reserved
Write 0s for future compatibility
RW
0x0000
Read returns 0
15:0
STATUS
Status value
RW
0x0000
8/9/12/16 bit value depending on the parallel mode
[7:0] 8-bit Data type
[8:0] 9-bit Data type
[11:0] 12-bit Data type
[15:0] 16-bit Data type
Table 7-265. Register Call Summary for Register RFBI_STATUS
Display Subsystem Basic Programming Model
•
:
•
Display Subsystem Register Manual
•
•
:
Table 7-266. RFBI_CONFIGi
Address Offset
0x60+ (i* 0x18)
Index
i = 0 to 1
Physical address
0x4805 0860+ (i* 0x18)
Instance
RFBI
Description
The control register allows configuration #I of the RFBI module.
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Reserved
Reserved
L4FORMAT
DATA
TYPE
A0POLARITY
CSPOLARITY
REPOLARITY
UNUSEDBITS
WEPOLARITY
CYCLEFORMAT
TRIGGERMODE
PARALLEL
MODE
HSYNCPOLARITY
TIMEGRANULARITY
TE_VSYNC_POLARITY
1874
Display Subsystem
SWPU177N – December 2009 – Revised November 2010
Copyright © 2009–2010, Texas Instruments Incorporated