Function
Using POPM instruction on Status register may result in device hang up
Description
When an active interrupt service request is pending and the POPM instruction is used to
set the Status Register (SR) and initiate entry into a low power mode , the device may
hang up.
Workaround
None. It is recommended not to use POPM instruction on the Status Register.
Refer to the table below for compiler-specific fix implementation information.
IDE/Compiler
Version Number
Notes
IAR Embedded Workbench
Not affected
TI MSP430 Compiler Tools (Code
Composer Studio)
v4.0.x or later
User is required to add the compiler
or assembler flag option below. --
silicon_errata=CPU21
MSP430 GNU Compiler (MSP430-
GCC)
MSP430-GCC 4.9 build 167 or later
CPU22
CPU Module
Category
Compiler-Fixed
Function
Indirect addressing mode with the Program Counter as the source register may produce
unexpected results
Description
When using the indirect addressing mode in an instruction with the Program Counter (PC)
as the source operand, the instruction that follows immediately does not get executed.
For example in the code below, the ADD instruction does not get executed.
mov @PC, R7
add #1h, R4
Workaround
Refer to the table below for compiler-specific fix implementation information.
IDE/Compiler
Version Number
Notes
IAR Embedded Workbench
Not affected
TI MSP430 Compiler Tools (Code
Composer Studio)
v4.0.x or later
User is required to add the compiler
or assembler flag option below. --
silicon_errata=CPU22
MSP430 GNU Compiler (MSP430-
GCC)
MSP430-GCC 4.9 build 167 or later
CPU36
CPU Module
Category
Functional
Function
PC corruption when single-stepping through flash erase
Description
When single-stepping over code that initiates an INFOD Flash memory erase, the
program counter is corrupted.
Advisory Descriptions
SLAZ340AF – OCTOBER 2012 – REVISED MAY 2021
MSP430F6723 Microcontroller
9