MSP430F23x
MSP430F24x(1)
MSP430F2410
SLAS547I – JUNE 2007 – REVISED DECEMBER 2012
www.ti.com
Compa
(1)
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
2.2 V
25
40
I
(DD)
CAON = 1, CARSEL = 0, CAREF = 0
µA
3 V
45
60
2.2 V
30
50
CAON = 1, CARSEL = 0, CAREF = 1/2/3,
I
(Refladder/RefDiode)
µA
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2
3 V
45
71
Common-mode input
V
IC
CAON = 1
2.2 V, 3 V
0
V
CC
- 1
V
voltage range
Voltage at 0.25 V
CC
PCA0 = 1, CARSEL = 1, CAREF = 1,
V
(Ref025)
2.2 V, 3 V
0.23
0.24
0.25
node / V
CC
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2
Voltage at 0.5 V
CC
node / PCA0 = 1, CARSEL = 1, CAREF = 2,
V
(Ref050)
2.2 V, 3 V
0.47
0.48
0.5
V
CC
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2
PCA0 = 1, CARSEL = 1, CAREF = 3,
2.2 V
390
480
540
See
Figure 36
and
V
(RefVT)
No load at P2.3/CA0/TA1 and P2.4/CA1/TA2,
mV
Figure 37
3 V
400
490
550
T
A
= 85°C
V
(offset)
Offset voltage
(2)
2.2 V, 3 V
-30
30
mV
V
hys
Input hysteresis
CAON = 1
2.2 V, 3 V
0
0.7
1.4
mV
T
A
= 25°C, Overdrive 10 mV,
2.2 V
80
165
300
Without filter: CAF = 0
(3)
ns
Response time
3 V
70
120
240
(see
Figure 32
and
Figure 33
)
t
(response)
(low-to-high and high-to-
T
A
= 25°C, Overdrive 10 mV,
2.2 V
1.4
1.9
2.8
low)
Without filter: CAF = 1
(3)
µs
3 V
0.9
1.5
2.2
(see
Figure 32
and
Figure 33
)
(1)
The leakage current for the Compa terminals is identical to I
lkg(Px.y)
specification.
(2)
The input offset voltage can be cancelled by using the CAEX bit to invert the Compa inputs on successive measurements. The
two successive measurements are then summed together.
(3)
The response time is measured at P2.2/CAOUT/TA0/CA4 with an input voltage step, with Compa already enabled (CAON = 1).
If CAON is set at the same time, a settling time of up to 300 ns is added to the response time.
58
Submit Documentation Feedback
Copyright © 2007–2012, Texas Instruments Incorporated