LMK04832EVM-CVAL User’s Guide
Table 3. Integrated VCO PLL
(1)
(continued)
PARAMETER
LMK04832-SP
UNIT
VCO0
VCO1
Phase Detector Frequency
122.88
MHz
Frequency
2457.6
2949.12
MHz
Kvco
13.0
25.0
MHz/V
N
20
24
Phase Margin
68
71
degrees
Loop Bandwidth
210
326
kHz
4
Default TICS Pro Mode
TICS Pro saves the state of the selected LMK04832-SP device when exiting the software. To ensure a
common starting point, the following modes listed in
may be restored by clicking
Default
configuration
and selecting the appropriate device configuration.
Table 4. Default TICS Pro Modes for the LMK04832-SP
DEFAULT TICS PRO MODE
DEVICE MODE
CLKin FREQUENCY
OSCin FREQUENCY
CLKin1 122.88 MHz, OSCin 122.88 MHz, VCO1
2949.12 MHz
Dual PLL, Internal VCO
122.88 MHz
122.88 MHz
Figure 3. Selecting a Default Mode for the LMK04832-SP Device
5
Using TICS Pro to Program the LMK04832-SP
This section will demonstrate how to use TICS Pro. For more information on using TICS Pro, refer to
. TICS Pro is available for download at
http://www.ti.com/tool/ticspro-sw
.
Before proceeding, be sure to follow the instructions in
to ensure proper hardware connections.
5.1
Start TICS Pro Application
Click
Start
→
Programs
→
Texas Instruments
→
TICS Pro
.
The TICS Pro program is installed by default to the Texas Instruments application group.
5.2
Select Device
Click
Select Device
→
Clock Generator/Jitter Cleaner (Dual Loop)
→
LMK04832-SP
.
Once started, TICS Pro will load the last used device. A recent history of used devices can be quickly
accessed under the
File
Menu. To load a new device, click
Select Device
from the menu bar, select the
subgroup, then select the device to load.