Additional Resources
Figure 3-12. Custom Sensor Connection
By default, the Evaluation Module is fitted with a 100pF 1% NP0 sensor capacitor in parallel to the PCB
coil. When the sensor capacitor value is changed as a result of replacing the default LC tank with a
custom inductive sensor, it is necessary to input the new capacitor value into the Sensor Capacitor field in
the GUI to ensure that the inductance data is calculated correctly.
Figure 3-13. Sensor Capacitor Setting
3.11 Additional Resources
Several resources are included in the GUI installation directory (typically C:\Program Files (x86)\Texas
Instruments LDC1000 EVM). These resources can be useful for development of LDC10xx projects.
3.11.1 PCB Information
In the installation directory, refer to the PCB subdirectory. In the PCB/Fabrication Drawing subdirectory the
schematic, Bill of Materials, and a printout of the layout is included. The Gerbers and manufacturing files
are included the PCB/Gerber subdirectory.
3.11.2 Firmware Resources
In the installation directory, refer to Firmware subdirectory. The firmware image is provided, along with the
source code and Code Composer project workspace for the LDC10xx EVM firmware.
3.11.3 Matlab Interface
A Matlab interface library is included in the installation. Refer to installation directory and then navigate to
Matlab\Doc\html\index.html for documentation on the provided functions.