Test Procedure
5.4.6
Efficiency Test (700-mA Load)
•
Verify that input current to TX is less than 350 mA with input voltage at 19 V
DC
•
Turn
OFF
Transmitter Power Supply (19)
5.4.7
Adapter Test (700-mA Load)
•
Connect 6-V, ±200 mV power supply with current limit set to 1.0 A to J1 and return to J2 on the
HPA764-005 receiver.
•
Adjust load current to 700 mA, ±50 mA
•
Turn on power supply
•
Verify that:
1. UUT: TP7 V
OUT
is 6.5 V to 7.1 V
2. Transmitter: Status LED D5 is off