Procedure
2.4.1
AC Adapter Detection Threshold
2.4.2
Selection of Regulation Voltage
Test Summary
www.ti.com
Figure 1. Original Test Setup for HPA206 (bq24740EVM)
1. Make sure the Equipment Setup steps of the previous section are followed.
2. Enable the output of PS#2.
3. Turn on PS#1.
Measure
→
V(J8(VSYS)) = 0
±
500 mV
Measure
→
V(TP(VREF)) = 0
±
1 V
Measure
→
V(TP(REGN)) = 0 V
±
500 mV
4. Increase the output voltage of PS#1 until D7 (EXTPWR) is on, but do not exceed 20 V.
Measure
→
V(TP(ACDET)) = 2.4 V
±
200 mV
Measure
→
V(J1(POS)) = 17.9 V
±
1 V
Measure
→
V(J8(SYS)) = 17.9 V
±
1 V
Measure
→
V(TP(VREF)) = 3.3 V
±
200 mV
Measure
→
D2 (BYPASS) on. D3 (ACDRV) on.
Observe
→
D5 (CHGEN) off (for bq24740 only), D5 (CE) on (for bq24741 only).
1. Increase the voltage of PS#1 until V(J1(POS)) = 19 V
±
0.1 V.
Measure
→
V(J8(BAT, GND)) = 0 V
±
2 V
Uninstall J20 enable the charging (for bq24740 only)
Observe
→
D5 (CHGEN) on
Install J20 enable the charging (for bq24741 only)
Observe
→
D5 (CE) off
Measure
→
V(TP(REGN)) = 6 V
±
500 mV
Measure
→
V(J8(BAT)) = 12.6 V
±
200 mV
2. Install J13 (CELLS, VPULUP)
Measure
→
V(J8(BAT)) = 16.8 V
±
200 mV
3. Install J13(CELLS, GND)
Measure
→
V(J8(BAT)) = 12.6 V
±
200 mV
bq24740/1EVM (HPA206) For Multicell Synchronous Notebook Charger