AMC7812EVM Software Overview
The input range can be adjusted by clicking the button next to each ADC channel on the right-hand side of
the page. Conversions can be triggered by pressing the
Start Conv
button or can be automatically
triggered before every read by enabling the
Auto-Trigger
check box. The ADC data registers, displayed on
the right side of the GUI, are updated with the converted results when the
Read ADC
button is pressed.
NOTE:
The AMC7812EVM includes two OPA2320 devices, which are configured to buffer the
ADC2/ADC3 inputs. By default, the two inputs are connected to ground, this is accomplished
by using the J7 shunts. The default configuration for the shunts are located in
. To
use the channels, remove the shunts and apply the desired voltage input to ADC2 or ADC3.
Most of the controls listed within the ADC image are used to setup the ADC configuration register. These
include the
conversion rate
and
conversion mode
parameters, which are selectable through their
respective dropdown list. The selectable conversion rates are listed in
Table 9. Conversion Rates
Throughput (ADC0–ADC11)
Conversion Rate
(Single-Channel Auto Mode)
00
500 kSPS
01
250 kSPS
10
125 kSPS
11
62.5 kSPS
The conversion mode can be either
Auto
or
Direct
mode. In
Direct Mode
, the analog inputs, specified in
the ADC channel registers, are converted sequentially one time. In
Auto Mode
, the analog inputs are
converted sequentially and repeatedly. After a conversion is completed, the ADC multiplexer returns to the
first channel and repeats the process.
The ADCs also have an option to use an
External
or
Internal
reference. Select this option by using a
dropdown menu, then choosing the
External
or
Internal
option. When the
Internal
option is chosen, the
ADC External Ref Value
box is grayed out. But when an
External
reference option is selected, the
ADC
External Ref Value
box becomes active and the value of external reference voltage can be entered in the
box as shown in
Figure 16. ADC External Ref Value
The
ADC Report
window displays the decimal value for each activated ADC channel. If the
Auto Read
button is pressed, the graph periodically updates with the new ADC value. To obtain new data, setup the
device for either Auto mode or Direct mode. If in Direct mode, verify that the
Trigger ADCs before read?
button is enabled. To stop the periodic updates press the
Auto Read
button once again.
shows
the
ADC Report
window. Additionally, the
Clear ADC Data
button clears the memory of the chart.
16
AMC7812EVM-PDK User’s Guide
SBAU177D – September 2010 – Revised August 2014
Copyright © 2010–2014, Texas Instruments Incorporated