4 Known Issues and Modifications
This section describes the currently known issues on each EVM revision and applicable workarounds. Issues
that have been patched will have modification labels attached to the EVM assembly. These modification labels
can be found as shown in
Table 4-1. AM64x/AM243x EVM Known Issues and Modifications
Issue Number
Modification Label
Number
Issue Title
Issue Description
1
N/A
Embedded XDS110 connection issue
Embedded XDS110 fails to
connect to AM64x target in CCS
after first EVM power cycle.
2
N/A
DC Barrell Jack Warning when Hot Plugging
Potential for board damage if hot-
plugging DC side.
Figure 4-1. AM64x/AM243x EVM Modification Label Location
4.1 Issue 1 - Embedded XDS110 Connection to AM64x Target in CCS
Applicable EVM Revisions
: All
Issue Description
: On some EVM, the embedded XDS110 (U59) has been shown to fail initial target connection
to AM64x target in CCS after first EVM and XDS110 power cycle. No problem exists when using an attached,
external emulator over the CTI20 header (J25).
This failure mode can be encountered by following the steps below:
1. XDS110 USB is attached between host PC and XDS110 USB port (J28).
2. EVM power is enabled and the AM64x is brought up in
no-boot
mode.
3. In CCS, an initial CCS target connection to the M3 DMSC core is then attempted.
Known Issues and Modifications
58
AM64x/AM243x EVM User's Guide
Copyright © 2022 Texas Instruments Incorporated