Figure 3-29. AM64x/AM243x CAN Interfaces
3.4.15 Interrupt
The EVM supports the following timer and interrupt options.
Three push button switches are available to provide reset for MCU_PORz and MCU_RESETz and
RESET_REQz. One push button switch is available for GPIO interrupt, which is connected to both main domain
and MCU domain GPIO pin.
Warm reset can also be applied through Test automation header or manual reset switches SW4 (SoC) and SW6
(MCU).
Power on reset input can be applied though switch SW7.
3.4.16 ADC Interface
A 20-pin connector J3 of part number TSW-110-07-S-D for connecting ADC signals of the AM64x/AM243x. The
connector includes ADC0_AIN0-7, VDDA_ADC connections and ground connections.
Table 3-26. ADC Connector (J3) Pin-out
Pin No.
Signal
Pin No.
Signal
1
DGND
11
ADC0_AIN7
2
NC
12
DGND
3
ADC0_AIN6
13
DGND
4
VDDA_ADC
14
ADC0_AIN1
5
DGND
15
ADC0_AIN0
6
ADC0_AIN2
16
DGND
7
ADC0_AIN5
17
VDDA_ADC
8
DGND
18
ADC0_AIN3
9
DGND
19
NC
10
ADC0_AIN4
20
DGND
System Description
54
AM64x/AM243x EVM User's Guide
Copyright © 2022 Texas Instruments Incorporated