background image

 
 

 

 

 

SNAU120-April 2012 

 

 

 

 

 

 

 

ADC161S626BEB User’s Guide 

11 

 

 

 

 

  

 

 

EVALUATION BOARD/KIT/MODULE (EVM) 

WARNINGS, RESTRICTIONS AND DISCLAIMERS 
 
For Feasibility Evaluation Only, in Laboratory/Development Environments

.  Unless otherwise indicated, this 

EVM is not a finished electrical equipment and not intended for consumer use.  It is intended solely for use for 
preliminary feasibility evaluation in laboratory/development environments by technically qualified electronics experts 
who are familiar with the dangers and application risks associated with handling electrical mechanical components, 
systems and subsystems. It should not be used as all or part of a finished end product. 

 
Your Sole Responsibility and Risk. 

You acknowledge, represent and agree that: 

 
1.  You have unique knowledge concerning Federal, State and local regulatory requirements (including but not 

limited to Food and Drug Administration regulations, if applicable) which relate to your products and which 
relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for 
evaluation, testing and other purposes. 

 
2.  You have full and exclusive responsibility to assure the safety and compliance of your products with all such 

laws and other applicable regulatory requirements, and also to assure the safety of any activities to be 
conducted by you and/or your employees, affiliates, contractors or designees, using the EVM. Further, you are 
responsible to assure that any interfaces (electronic and/or mechanical) between the EVM and any human 
body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the 
risk of electrical shock hazard. 

 
3.  You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property 

damage, injury or death, even if the EVM should fail to perform as described or expected. 

 
4.  You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials. 
 

Certain Instructions

. It is important to operate this EVM within TI’s recommended specifications and 

environmental considerations per the user guidelines. Exceeding the specified EVM ratings (including but not 
limited to input and output voltage, current, power, and environmental ranges) may cause property damage, 
personal injury or death. If there are questions concerning these ratings please contact a TI field representative 
prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the 
specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to 
the EVM and/or interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM 
output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal 
operation, some circuit components may have case temperatures greater than 60

o

C as long as the input and output 

are maintained at a normal ambient operating temperature. These components include but are not limited to linear 
regulators, switching transistors, pass transistors, and current sense resistors which can be identified  using the 
EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during 
normal operation, please be aware that these devices may be very warm to the touch. As with all electronic 
evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found 
in development environments should use these EVMs. 
 

Agreement to Defend, Indemnify and Hold Harmless

. You agree to defend, indemnify and hold TI, its licensors 

and their representatives harmless from and against any and all claims, damages, losses, expenses, costs and 
liabilities (collectively, "Claims") arising out of or in connection with any use of the EVM that is not in accordance 
with the terms of the agreement. This obligation shall apply whether Claims arise under law of tort or contract or 
any other legal theory, and even if the EVM fails to perform as described or expected.  
 

Safety-Critical or Life-Critical Applications

. If you intend to evaluate the components for possible use in safety 

critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause 
severe personal injury or death, such as devices which are classified as FDA Class III or similar classification, then 
you must specifically notify TI of such intent and enter into a separate Assurance and Indemnity Agreement. 

Summary of Contents for ADC161S626BEB

Page 1: ...ase evaluation of the ADC161S626 With the optional SPIO4 board and optional Sensor board the board allows evaluation of an entire Sensor AFE system The evaluation board can be used in stand alone mode in which the user interfaces with the part through the SPIO GPSI16 connector and applies input signals on the AB12 connector The board can also be used with an SPIO4 board in place of an external pat...

Page 2: ...the SPIO4 board GPSI16 16 pin dual row right angle female header Carries signals from the SPIO4 board to any optional SensorAFE board AB12 12 pin dual row right angle male header Carries analog bus signals from an external source or the optional Sensor AFE board to the ADC Table 2 Connectors on the ADC161S626 Evaluation Board Jumper Purpose VREF SELECT Selects reference source for VREF Settings ar...

Page 3: ... This will connect the ADC VREF line to the 4 096V on board LM4120 reference Ensure that a 4MHz crystal is installed in the socket Y2 and that there is no signal applied at the CLK IN BNC jack Connect the SPIO4 board to the ADC161S626BEB board at the SPIO GSPI16 male header Line up the white arrows on the bottom of the headers Connect the LMP91000 board to the GPSI16 and AB12 headers Line up the w...

Page 4: ...to generate a clock for the SPIO4 board o Bring a clock to the SPIO GPSI16 header from an external board of your choice 4 Functional Description 4 1 ADC Reference Circuitry This evaluation board includes three options to source the voltage reference VREF The options are selecting the fixed on board 4 096V voltage reference LM4120 4 1 to source VREF connecting VREF to VA of the device or using the ...

Page 5: ...SNAU120 April 2012 ADC161S626BEB User s Guide 5 5 Hardware Schematic ...

Page 6: ...PIO GPSI16 Header 8 Pin Dual row Right Angle Sullins Connector Solutions PBC36DGAN 2 9 VA SELECT Header TH 100mil 1x2 Gold plated 230 mil above insulator Samtec Inc TSW 102 07 G S 1 10 VIO SELECT VREF SELECT Header TH 100mil 1x3 Gold plated 230 mil above insulator Samtec Inc TSW 103 07 G S 2 11 U6 IC EEPROM 2KBIT 400KHZ 8TSSOP ON Semiconductor CAT24C01WI GT3 1 12 Y2 OSC 4 000 MHZ 5 0V FULL SIZE EC...

Page 7: ...gement of patents or services described herein Mailing Address Texas Instruments Post Office Box 655303 Dallas Texas 75265 Copyright 2012 Texas Instruments Incorporated REGULATORY COMPLIANCE INFORMATION As noted in the EVM User s Guide and or EVM itself this EVM and or accompanying hardware may or may not be subject to the Federal Communications Commission FCC and Industry Canada IC rules For EVMs...

Page 8: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televi...

Page 9: ... de brouillage radioélectrique à l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente p i r e ne dépasse pas l intensité nécessaire à l établissement d une communication satisfaisante Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d antenne énumérés dans le manuel d u...

Page 10: ...技術基準適合証明を受けておりません 本製品のご使用に際しては 電波法遵守のため 以下のいずれかの措置を取っていただく必要がありますのでご注 意ください 1 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗 室等の試験設備でご使用いただく 2 実験局の免許を取得後ご使用いただく 3 技術基準適合証明を取得後ご使用いただく なお 本製品は 上記の ご使用にあたっての注意 を譲渡先 移転先に通知しない限り 譲渡 移転できないも のとします 上記を遵守頂けない場合は 電波法の罰則が適用される可能性があることをご留意ください 日本テキサス インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http www tij co jp ...

Page 11: ... limited to input and output voltage current power and environmental ranges may cause property damage personal injury or death If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads Any loads applied outside of the specified output range may result in unintended and or inaccurate op...

Page 12: ...warranties for the associated TI product or service and is an unfair and deceptive business practice TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an...

Page 13: ...SNAU120 April 2012 ADC161S626BEB User s Guide 13 Mailing Address Texas Instruments Post Office Box 655303 Dallas Texas 75265 Copyright 2007 Texas Instruments Incorporated ...

Reviews: