GASMOBILE
User Manual
www.elektropartner.com
Page 1: ...GASMOBILE User Manual www elektropartner com...
Page 2: ...RE DESCRIPTION 77 2 1 Browsing through Screens and Selecting 78 2 2 Service Icons 78 2 3 Service Messages 79 3 MAIN MENU 80 3 1 Preliminary Test Procedures 81 4 DIESEL MEASUREMENTS 82 4 1 Continuous m...
Page 3: ...3 4 Seal Test 119 5 3 5 Checks and Adjustments 120 6 SERVICE 121 6 1 Display 123 6 2 Date time 123 6 3 Bluetooth Periferals 124 6 3 1 Periferal Search 126 6 3 2 IPaddr from SD CARD 127 7 Legal informa...
Page 4: ...rk TEXA S p A is a company that designs and develops tools for multibrand analysis and emissions tests on cars motocycles and industrial vehicles Today it is one of Europe s most important companies i...
Page 5: ...l characteristics of the software 3 Main Menu describes the main menu of the software and preliminary test procedures 4 Diesel Measurements describes the emissions analysis functions for diesel engine...
Page 6: ...s keep in mind several behavioural rules explained in this chapter Below you will find the legend listing several conventional symbols used within this manual Indicates a potentially hazardous conditi...
Page 7: ...on vehicles i e engine checks ABS airbag air conditioning navigator radio Hi Fi system Nevertheless if a malfunction occurs you need to contact the retailer 2 Position the device making sure it can be...
Page 8: ...2 DO NOT carry out any type of intervention that may damage the tool or compromise its functioning 3 DO NOT drop hit or shake the device for it may cause irreparable damage to the internal circuits 4...
Page 9: ...tly lit and well ventilated Please note a car diagnosis which requires turning on and running the engine needs to be done in a place equipped with an exhaust fan system Inhalation of carbon monoxide o...
Page 10: ...ime the engine you are working on is still hot This will avoid the fan from becoming activated unexpectedly even when the engine is off Handle the portable lamps with care and use only those with meta...
Page 11: ...cables are being connected to the battery Avoid splashing electrolyte onto the skin into eyes or on clothes This substance is corrosive and highly toxic 1 5 Working with Appliances Powered by the Main...
Page 12: ...functions The software allows you to carry out Continuous measurement Official Test According to norms in effect in the country where the software and device have been officially approved These tests...
Page 13: ...and FORWARD BACK arrows allow you to select the items desired and allow you to set parameter values The OK key allows you to confirm the selection made or the value entered The C key allows you to exi...
Page 14: ...rs in communication with the emissions analysis tools ambient conditions do not correspond to those required in order to carry out the tests analysis tool calibration expired etc Messages provided by...
Page 15: ...ppear in this screen are as follows SMOKE METER allows you to access the tests for diesel engines DIESEL MEASUREMENTS GAS ANALYZER allows you to access the tests for petrol engines GAS MEASUREMENTS SE...
Page 16: ...he engine is running at idle if the exhaust seal is efficient you would not notice any gas leak from the joints the engine RPM at idle corresponds to that declared by the Manufacturer the temperature...
Page 17: ...are constantly monitored The program wherever possible will restore the optimal conditions for the test and will notify you of any problems that must be solved The test is stopped until the optimal m...
Page 18: ...EASUREMENT allows you to carry out continuous measurement tests OFFICIAL TEST allows you to carry out the Official Test SERVICE allows you to access the smoke meter service menu The program guides the...
Page 19: ...ty value You must have correctly configured the Bluetooth communication with the emissions analysis tool and with the rev counter Proceed as follows DIESEL MEASUREMENTS Select CONTINUOUS MEASUREMENT P...
Page 20: ...es for both temperature and RPM 1 Select SKIP CONNECTION 2 Press the OK key Selecting this option will take you directly to the screen CONTINUOUS MEASUREMENT REV COUNTER SETUP This screen appears only...
Page 21: ...This screen appears only if an external rev counter is used 86...
Page 22: ...ol CONTINUOUS MEASUREMENT The value of the following parameters is provided Parameter Unit of measurement Description K m 1 Opacity N Opacity in percentage K max m 1 Maximum opacity value recorded N m...
Page 23: ...RESET allows you to reset the measurements that have been carried out up til now QUIT allows you to quit the test Select the desired item Press the OK key 88...
Page 24: ...currently in effect You must have correctly configured the Bluetooth communication with the emissions analysis tool and with the rev counter Proceed as follows DIESEL MEASUREMENTS Select OFFICIAL TEST...
Page 25: ...he desired item Press the OK key OFFICIAL TEST DATA This screen allows you to set the data required by the official standard ENGINE TYPE allows you to indicate the engine type of the vehicle on which...
Page 26: ...g the vehicle to a temperature over 80 C The limit value must be read in the engine approval plate located in the engine compartment and or in the door frame on the driver or passenger side If you are...
Page 27: ...onment pressure detected Relative humidity Environment humidity detected Select UPDATE Press the OK key The ambient data are updated The ambient data can be entered manually Select the desired item Se...
Page 28: ...t START CONNECTION 2 Press the OK key In order to manually enter the values for both temperature and RPM 1 Select SKIP CONNECTION 2 Press the OK key Selecting this option will take you directly to the...
Page 29: ...een appears only if an external rev counter is used The value of the following parameters is provided Parameter Unit of measurement Description STATUS Rev counter connection status TEMP deg C Temperat...
Page 30: ...perature and engine rpm In this screen you can set the threshold for Parameter Unit of measurement Description MIN RPM Minimum number of engine rpm MAX RPM Maximum number engine rpm OIL TEMP deg C Eng...
Page 31: ...when requested by the software and the engine must be kept at the appropriate rpm until the software asks you to bring the rpm to idle OFFICIAL TEST OUTCOME The test will end when the procedure descr...
Page 32: ...lt of the test is positive when the average of the values of the last three valid accelerations is within the limits defined by the Norm in effect Press the OK key The report of the test carried out i...
Page 33: ...t with in the next chapters The other functions are protected by an assistance password and are for TEXA technical personnel only Proceed as follows DIESEL MEASUREMENTS Select SERVICE Press the OK key...
Page 34: ...red item Press the OK key 4 3 1 Information This function allows you to view a summary of the sensitive data of the emissions analysis tool and of the rev counter INFORMATION Within this screen you ca...
Page 35: ...3 Calibration This function allows you to perform the calibration of the emissions analysis tool This function is protected by a password and is for technical assistance personnel only Press the Ckey...
Page 36: ...related to the measurement are constantly monitored The program wherever possible will restore the optimal conditions for the test and will notify you of any problems that must be solved The test is s...
Page 37: ...n are as follows CONTINUOUS MEASUREMENT allows you to carry out continuous measurement tests OFFICIAL TEST allows you to carry out the Official Test SERVICE allows you to access the smoke meter servic...
Page 38: ...ty value You must have correctly configured the Bluetooth communication with the emissions analysis tool and with the rev counter Proceed as follows GAS MEASUREMENTS Select CONTINUOUS MEASUREMENT Pres...
Page 39: ...both temperature and RPM 1 Select SKIP CONNECTION 2 Press the OK key Selecting this option will take you directly to the screen ENGINE FUEL REV COUNTER SETUP This screen appears only if an external re...
Page 40: ...S Rev counter connection status TEMP deg C Temperature detected RPM Number of RPM detected Press the OK key ENGINE FUEL This screen allows you to set the data required to perform the test ENGINE allow...
Page 41: ...Use the browser keys to set the data required Press the OK key The ambient conditions are checked An autozero is carried out on the tool 106...
Page 42: ...d NOx ppm Nitrogen oxide Toil deg C Engine oil temperature RPM Number of RPM detected Bretschneider Formula This parameter is given only if the appropriate sensor is installed on the tool The function...
Page 43: ...ard currently in effect You must have correctly configured the Bluetooth communication with the emissions analysis tool and with the rev counter Proceed as follows GAS MEASUREMENTS Select OFFICIAL TES...
Page 44: ...nimum limit for the engine oil temperature The engine oil temperature stated is the minimum value provided for by the norm in effect You are allowed to carry out the test at less than 80 C If the outc...
Page 45: ...value for the engine at idle MinAcc min allows you to indicate the minimum rpm value for the engine at accelerated idle MinAcc max allows you to indicate the maximum rpm value for the engine at accele...
Page 46: ...e OK key The ambient data are updated The ambient data can be entered manually 1 Select the desired item 2 Set the value desired 3 Press the OK key Press the OK key again once you have updated the amb...
Page 47: ...ect START CONNECTION 2 Press the OK key In order to manually enter the values for both temperature and RPM 1 Select SKIP CONNECTION 2 Press the OK key Selecting this option will take you directly to t...
Page 48: ...ENTS This screen appears only if an external rev counter is used The value of the following parameters is provided Parameter Unit of measurement Description STATUS Rev counter connection status TEMP d...
Page 49: ...vided Parameter Unit of measurement Description CO Carbon monoxide COcor Carbon monoxide correct CO2 Carbon dioxide 02 Oxygen HC ppm Hydrocarbons not burned NOx ppm Nitrogen oxide Toil deg C Engine oi...
Page 50: ...he test will end when the procedure described by the norm in effect has been completed The screen contains the outcome of the test Press the OK key The report of the test carried out is printed Press...
Page 51: ...lt with in the next chapters The other functions are protected by an assistance password and are for TEXA technical personnel only Proceed as follows GAS MEASUREMENTS Select SERVICE Press the OK key S...
Page 52: ...MENTS allows you to carry out a calibration of the emissions analysis tool Select the desired item Press the OK key 5 3 1 Information This function allows you to view a summary of the sensitive data o...
Page 53: ...Ckey to exit 5 3 3 Residual HC Test This function allows you to check if there are any residual hydrocarbons in the hydraulic circuit of the tool These residuals could alter the measurements The gas p...
Page 54: ...to exit 5 3 4 Seal Test This function enables you to check the hydraulic seal of the external and internal circuit of the tool Follow the instructions that appear on your screen until you come to the...
Page 55: ...econds If the outcome is negative the program suggests performing a second test Press the Ckey to exit 5 3 5 Checks and Adjustments This function allows you to access the data relative to the checks a...
Page 56: ...SERVICE MENU The items that appear in this screen are as follows DISPLAY allows you to set the contrast and brightness of the display DATE TIME allows you to set the date and time on the device BLUETO...
Page 57: ...Press the OK key 122...
Page 58: ...at appear in this screen are as follows CONTRAST allows you to set the contrast of the display BRIGHTNESS allows you to set the brightness of the display Use the browser keys to set the data required...
Page 59: ...me on the device Use the browser keys to set the data required Press the OK key 6 3 Bluetooth Periferals This function allows you to set the communication with the Bluetooth tools BLUETOOTH PERIFER Th...
Page 60: ...SD CARD IPaddr allows you to set the IP address of the Bluetooth devices saved on the SD CARD of the tool Select the desired item Press the OK key 125 en...
Page 61: ...tarts to search for Bluetooth tools within the workshop The tools can be selected if an empty rectangular box appears next to their serial number SELECT PERIFERALS The device will list the Bluetooth t...
Page 62: ...y one gas analyzer only etc Press the Ckey to exit 6 3 2 IPaddr from SD CARD This function allows you to set the IP address of the Bluetooth devices saved on the SD CARD of the tool BLUETOOTH PERIFER...
Page 63: ...and describes optional and standard features of the product The tool you have purchased may not be equipped with certain features or elements described in this document This manual should be consider...
Page 64: ...ly by TEXA S p A or by the retailer or through programs and user manuals knowing that these may be incomplete and that they must always be used as an integration to her his own professional knowledge...