Edition: 24.06.2019
Before each use the recue loop must be checked for:
1. Integrity of the components:
- Webbing: there shall be NO tears , cuts , lintings ,discolorations, burns or melted areas;
- Stitchings: yarn must be continuous , no breaks, no skipped steps;
2. Compatibility of other components intended to be used with the rescue loop;
3. Label information;
4. Cleannes of the equipment;
Equiping the rescue loop:
A. The rescue strap shall be equipped in accordance with Fig. A. passing the legs through the back support strap, then through the two
loops that will support the legs (similar to pants /trousers dressing);
B. Ensure that all straps are positioned correctly, as shown in Fig. A ,supporting both legs and the back of the person (under his/her
arms!) Make sure the straps are not twisted!
C. Attach a certified connector (EN 362) in between the safety line and the attachment loop and ensure that it is properly closed and
locked;
WARNING! It is forbidden to use this rescue loop to assure an user against falling from heights (in fall arrest systems) or for other
purposes rather than the one described in these instructions!
WARNING! The rescuer must ensure that the person (rescuee) will not be endangered by any elements present at the rescue site or
by unintended contact with other equipment used in the rescue operation (e.g. a strike to the head by a metallic connector).
WARNING! Prolongued suspension onto the equipment may lead to suspension trauma, which can cause loss of consciousness or, in
extreme cases, even death!
The equipment must be immediatelly removed from service if:
1.The marking/label is missing or is unreadable.
2.Damage has been identified (incisions, worn seams, cuts, discoloration, hardened or thinned areas, burns) or if any
abnormalities of the parts or structure have been found.
3.Contact with paints or unknown chemicals had occurred (irreversible contaminations).
4.The harness was involved in a fall arrest or had been subjected to heavy loading.
5.The integrity of the equipment is questionable and the inspection log is incomplete or missing.
6.The equipment was in service longer than 10 years.
Repairs or any other modifications can be performed only by the manufacturer! Any repairs, modifications or additions (even minor
ones) performed by anyone else are strictly forbidden, lead to the loss of the manufacturers guarantee and any responsibility related to
this product!
STORAGE, MAINTENANCE, TRANSPORT
The equipment should be stored in a dry, cool and well-ventilated room, if possible, in its original packaging. While in storage, this
equipment must be protected from UV radiation, solar radiation, heat, sparks, incandescent metal splash, electricity, chemicals, sharp
objects, heat sources, dust, cement, oils and greases or any kind of contaminants. If necessary, the textile parts can be claned using
warm water (30°C) then rinsed. Drying the wet equipment will be made by hanging it in well-ventilated room away from any heat source.
When fully dried, the equippment can be storred accordingly in its packaging (bag or box). Transport of the equipment must be made in
its protective bag or box, away from any factor that could contaminate or inflict damage.
Service Life
The service life, under normal conditions of use is 8-10 years, from the date of the first use and can reach max. 10 years(*). The date
of first use must be written in the inspection log! The storage of new, unused products, under optimal conditions (dark, cool, dry, clean,
no chemical vapors or gases, kept in original packing) should not exceed 2 years. If the storage time has exceeded 2 years the extra
time spent will be subtracted from the service life.