1/2
1
PRE-INSTALLATION CHART
Art. T50
Hydroline
(h: mm 590)
67101076400 2015.02
R 6
62
0
1700
1768 ±
1
688 ±
1
44
±
1
1766 ±
1
1766 ±
1
50
0
1730
1766 ±
1
430
680
480
85
85
min 20
0
1950
min 98
5
85
min 20
0
620
1700
1780
680
1760
700
507
1295
J
I
1/2"
Facing for sunken
installation
Facing for flush
installation
ELECTRICAL CHARACTERISTICS
V
Hz
Power consumption
W
K074 (optional)
220 - 240
50/60
15
MY / MY-F
220 - 240
50/60
1000
HYDRAULIC CHARACTERISTICS
Water capacity (1)
lt
Emptying time (2)
min.
No. of Jets
Overflow water flow
rate
l/min.
310
9
32
-
8
Net Weight
kg
Floor Load
kg/m
2
Delivery Weight
kg
Delivery dimensions
cm
68
450
101
191 x 82 x 83
N.B. Measurements must be taken once the floors and walls are finished. For the
correct operation of the product, we recommend installing it on surfaces where
floor level heating is not used.
BATHTUB INSTALLATION
It is advisable to position the bathtub, make the necessary connections and
check the water-tightness of the system before building the perimeter walls.
Before building the perimetre walls, it is advisable to position the bathtub and
make the necessary connections. It is mandatory to create a removable panel
on the side of the tank (l), as shown in the relevant picture, which allows both
system inspection and ventilation; the panel must be provided with openings,
of at least 0,05 sqm in total, to allow system ventilation. Build the perimeter
wall also on taps and control side and always provide an inspection panel (J)
to carry out system maintenance operations, as shown in the picture. When
making the panel, follow the dimensions indicated in the diagram. The panel must
be fastened securely in place (e.g. with screws) so that a tool must be used to
remove it, as provided for by current safety standards. Envisage a clearance of at
least 40 cm in front of the removable panels.
(1) At overflow level - (2) Measurement taken at Teuco siphon outlet, with the bathtub filled up to overflow level.
Measurements in mm
- Connection of water mixed for ½” water sheet spout
- Electrical connection
I, J - Inspection and ventilation panels