CC901AG
7-4
Tetra Pak
Hoyer
Fig. 7.3
Fig.7.4
2
1
1
3
4
5
6
6
2
1
3
4
5
7.5 Topping maintenance
7.6 Pencil filler maintenance
Each day, at the end of the working cycle use the
dosing pump to pump warm water through the
feed pipe.
Periodically, and when required, dismantle the
doser nozzle (Pos.1, Fig.7.4) and the cover (Pos.2,
Fig.7.4).
When the doser dismantled, check the efficiency
of the O-rings (Pos.3-4-5, Fig.7.4).
Wash using the recommended products (see
washing table), and reassemble.
Each day, at the end of the working cycle use the
dosing pump to pump warm water through the
chocolate feed pipe.
Periodically, and when required, dismantle the
ends of the doser (Pos.1, Fig.7.3) and the cover
(Pos.2, Fig.7.3).
With the doser dismantled, check the efficiency
of the O-rings (Pos.4-5-6, Fig.7.3) .
Wash using the recommended products (see
washing table), and reassemble.