background image

 

Instruction Manual 

 

 

 

CLEANING OF THE STRAINER BASKET 

 

1.

 

The strainer basket requires periodic cleaning to operate effectively and efficiently. 

2.

 

A routine inspection should be done by visually looking through clear strainer lid for debris while the pump is in operation. The 
strainer basket should be cleaned when approximately 25 % blocked. Allowing the strainer 

3.

 

basket to become excessively blocked will diminish water flow, reduce pump efficiency, possibly cause cavitation and may damage 
the basket or pump. 

4.

 

Disconnect power to the pump before cleaning the basket. 

5.

 

Close valves on thesuction and discharge lines if necessary to prevent flooding. 

WARNING:

 The strainer pot may be at a pressure that is higher or lower than the atmospheric pressure. Always 

open the drain plug on the strainer pot and allow for the pressure to equalize before removing the clear lid. 
Attempting to remove the lid before the pressure is equalized may result in a rapid pressure release.  
 
 

For Repair Parts, contact dealer where unit was purchased. 

Please provide following information: 

-Model number 

-Serial number (if any) 
-Part description and number as shown in parts list 
 

 

Figure 1 - Repair Parts Illustration

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Please  read  and  save  these  instructions.  Read  carefully  before  attempting  to  assemble,  install,  operate  or  maintain  the 

product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could 

result in personal injury and/or property damage! Retain instructions for future reference. 

 

 

 

        Repair Parts List 

Part # 

Lid 

BSLID 

2  Lid o-ring 

BSLOR 

3  Strainer basket 

BSBSK 

1 1/2"Discharge split nut (Buttress Thd.) 

BSSN1.5 

4  2" Discharge split nut (Buttress Thd.) 

BSSN 

5  Gasket w/ridge 

711.4031 

6  Drain plug w/ o-ring 

715.1201 