Instruction Manual
2
CLEANING OF THE STRAINER BASKET
1.
The strainer basket requires periodic cleaning to operate effectively and efficiently.
2.
A routine inspection should be done by visually looking through clear strainer lid for debris while the pump is in operation. The
strainer basket should be cleaned when approximately 25 % blocked. Allowing the strainer
3.
basket to become excessively blocked will diminish water flow, reduce pump efficiency, possibly cause cavitation and may damage
the basket or pump.
4.
Disconnect power to the pump before cleaning the basket.
5.
Close valves on thesuction and discharge lines if necessary to prevent flooding.
WARNING:
The strainer pot may be at a pressure that is higher or lower than the atmospheric pressure. Always
open the drain plug on the strainer pot and allow for the pressure to equalize before removing the clear lid.
Attempting to remove the lid before the pressure is equalized may result in a rapid pressure release.
For Repair Parts, contact dealer where unit was purchased.
Please provide following information:
-Model number
-Serial number (if any)
-Part description and number as shown in parts list
Figure 1 - Repair Parts Illustration
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could
result in personal injury and/or property damage! Retain instructions for future reference.
Repair Parts List
Part #
1
Lid
BSLID
2 Lid o-ring
BSLOR
3 Strainer basket
BSBSK
4
1 1/2"Discharge split nut (Buttress Thd.)
BSSN1.5
4 2" Discharge split nut (Buttress Thd.)
BSSN
5 Gasket w/ridge
711.4031
6 Drain plug w/ o-ring
715.1201