30 |
P a g e
OPERATION
End of procedure
D
RYING
R
ACKS AND OTHER
A
CCESSORIES
•
Make sure any accessories used inside the oven chamber, such as drying racks, are
suitable for your application and will not suffer damage when brought to temperature.
•
Always set the OTL cutoff system to just above your application temperature set point in
order to safeguard accessories against over temperature events.
•
The manufacturing defect warranty does not cover damage caused by melted or otherwise
overheated accessory items.
Setting the Timer Continued
5
Use the
Up
or the
Down arrow key
to set the Tens of
Minutes parameter value.
Set Timer
1 Hour, 51 Minutes
6
Advance to the Minutes parameter.
a.
Press and hold the
Reset
button.
•
The flashing decimal point will advance to
behind the 4
th
number, automatically saving the new
Tens-of-Minutes parameter setting.
Set Timer
Minutes Selected
7
Use the
Up
or the
Down arrow key
to adjust the Minutes
parameter value.
Set Timer
1 Hour, 55 Minutes
8
Wait for 5 seconds after entering the new Minutes parameter
value.
•
The display will exit adjustment mode.
•
The Minutes parameter, along with the
previous two parameter values are now saved.
Set Timer
Summary of Contents for FOV Series
Page 2: ...2 P a g e This page left blank...
Page 18: ...18 P a g e INSTALLATION This page left blank...