8. Specifications
TT-SI 9010
Bandwidth
DC to 70MHz (-3dB)
Attenuation Ratio
1:100 / 1:1000
Accuracy ±2%
Rise Time
5ns
Input Impedance
10M
Ω
// 10pF each side to ground
Input Voltage
- Differential Range
1:100 ±700V (DC+peak AC) or 700Vrms
1:1000 ±7000V (DC+peak AC) or 5000Vrms
Input Voltage
- Common Mode Range
1:100 and 1:1000
±7000V (DC+peak AC) or 2500Vrms
Input Voltage
- Absolute Max.
Common Mode
1:100 and 1:1000
±7000V (DC+peak AC)
or 2500Vrms
Input Voltage
- Absolute Max.
Differential Mode
1:100 and 1:1000
±7000V (DC+peak AC)
or 5000Vrms
Measurement Category
CAT I
Output Voltage
- Swing
±7V (into 50k
Ω
load)
Output Voltage
- Offset (typical)
<±5mV
Output Voltage
- Noise (typical)
0,9mVrms
Source Impedance (typical)
50
Ω
(for using 1M
Ω
input system oscilloscope)
CMRR (typical)
-80dB @50Hz, -60dB @20kHz
Ambient Operating
Temperature
-10
°
C to 40
°
C
Ambient Storage Temperature -30°C to 70
°
C
Ambient Operating Humidity 25% to 85% RH
Ambient Storage Humidity 25% to 85% RH
Power Requirements
- Standard
4 x AA Cells
Power Requirements
- Optional
Power lead or Mains Adapter
(6VDC/60mA or regulated 9VDC/40mA)
Length of BNC Cable 90cm
Length of Input Leads 60cm
Weight 500g
Dimensions (LxWxH)
202mm x 83mm x 38mm
a. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the probe
could be damaged or can’t be operated properly.
b. Polarity is “+” inside and “–” outside. For wrong polarity, built-in circuit protects the
probe, no danger or damage will occur.
c.
When the voltage of the cells become too low, the power indicator on the will flicker
.