TI2560 12-24 GPU
30
6
Troubleshooting & FAQ
Fault
Possible Cause
Remedy
7. Circuit breaker continuously
trips
Unit is overheating.
A.
Disconnect unit from ac input and dc
A.
output.
Switch breaker to ON position.
B.
Reconnect unit to cables and run.
C.
If LEDs still do not illuminate, Please
D.
contact Tesla™ Customer Service at
(302) 324-8910.
8. Unit does not put out 28.5
volts dc power.
Unit is not plugged in.
A.
Plug unit into ac power source to
A.
maintain 28.5.
Stand alone Vdc is 24 Volts
B.
(unplugged).
9. Unit stand alone voltage is
less than 23 volts.
Cells discharged.
A.
Plug unit into ac power source.
A.
Recheck capacity after 25 minutes.
B.
Failure to hold above 23 Vdc, Please
C.
contact Tesla™ Customer Service at
(302) 324-8910.
10. Unit weakens after fi rst
start.
Weak cells.
A.
Allow between 30 to 60 seconds
A.
backcharge between uses.
Troubleshooting for the Pure Sine-Wave Inverter is continued on the next page.