7

Before the first start, carefully familiarize yourself with all the functional settings and features of the control 

panel of the air conditioner and its remote control.
The air conditioner can be controlled separately both from the control panel and from the remote control 

(only for remotely controlled models).

AIR CONDITIONING PANEL

FUNCTION BUTTONS AND INDICATORS

1

 

POWER Button (ON / OFF)

Turns on / off the power of the air conditioner.

2

 

“NIGHT MODE” button (“SLEEP”)

Used to start the air conditioner in the "NIGHT" mode.

3

 

FAN Button (FAN / ION)

 (

ION - optional

)

Used to select the fan speed. Each time you press this button, the fan speed changes in the following 

sequence: LOW - MEDIUM - HIGH - AUTO (LOW - MED - HI - AUTO), after which the cycle repeats again. 

When LOW, MEDIUM, and HIGH fan speeds are selected, the corresponding indicators light up on the 

control panel. When AUTO is selected, they are all highlighted with a dimmer light.

NOTE: Press and hold this button for 3 seconds to start ION functions. In this case, the ion generator is 

activated, which helps to remove pollen and other impurities from the air by absorbing them by the filter. 

Pressing and holding this button again for 3 seconds will stop the ION function.

4

 

The “INCREASE” (+) and “REDUCE” buttons (-) (“UP” (+) and “DOWN” (-))

Used to adjust (increase / decrease) the temperature in increments of 1ºC (2 ° F) in the range of 17-30 ° C 

(62-88 ° F) or to set the timer in the range of 0 to 24 hours.

NOTE: The temperature on the control panel display can be displayed in degrees Celsius or Fahrenheit. To move 

from one degree to another, simultaneously press and hold the INCREASE (+) and REDUCE (-) buttons for 3 

seconds.

5

 

Button “MODE SELECTION” (“MODE”)

Selects the appropriate operating mode. Each time you press this button, the operating mode of the air 

conditioner changes in the following sequence: AUTO (AUTO) - COOLING (COOL) - DRY (DRY) - VENTILATION 

(FAN) - HEAT (HEAT) *, after which the cycle repeats again.

* - only in 

TE-PT-12KHC-BLG

 models with this functionality.

At various operating modes of the air conditioner, the corresponding symbols are highlighted on its control 

panel.

1

2

3

5

6

7

4

8

9

ION - Optional

Optional

Optional

CONTROL PANEL

Summary of Contents for NIKOLACOOL TE-PT-12KHC-BLG

Page 1: ...INSTRUCTIONS FOR USER TESLA AIR CONDITIONER PORTABLE MOBILE TYPE TE PT 12KHC BLG NIKOLACOOL www tesla com np...

Page 2: ...ND SAFETY PRECAUTIONARY MEASURES AIR CONDITIONER REVIEW CONTROL PANEL AIR CONDITIONER OPERATIONS MOUNTING INSTALLATION CARE MAINTAINANCE TIPS FOR TROUBLESHOOTING SPECIFICATIONS 2 3 5 5 6 7 8 9 10 11 1...

Page 3: ...2 www tesla com np...

Page 4: ...east 30 cm If the air conditioner is toppled over during use immediately turn off the appliance and disconnect it from the power source ATTENTION Do not use the air conditioner in rooms with high humi...

Page 5: ...ll the appropriate outlet Make sure that after installing the air conditioner the outlet will be within reach of the length of its power cord This device is not intended for use by persons including c...

Page 6: ...ir intake 7 Air outlet 8 Drain hole only for models with heating type of heat pump 9 Output for power cord 10 Staples for the power cord used only when storing the device 11 Lower drainage 12 Electric...

Page 7: ...s only for remote controlled models 1 Set drain hose for it 1 optional components some models are supplied without them NOTE Check the availability of accessories in the package If you have questions...

Page 8: ...case the ion generator is activated which helps to remove pollen and other impurities from the air by absorbing them by the filter Pressing and holding this button again for 3 seconds will stop the IO...

Page 9: ...ntrol at the air conditioner then press the button of the same name The remote control captures the actual air temperature at its location He will send this data to the air conditioner every 3 minutes...

Page 10: ...IN THE FAN MODE Press the MODE button until the FAN indicator lights up Using the FAN button set the required rotation speed However you cannot adjust the temperature You may not have to vent the duc...

Page 11: ...will continue to work in the settings that were set before the start of the Night mode NOTE Operation of the air conditioner in the NIGHT mode is not available if it operates in the VEN TILATOR mode...

Page 12: ...The air conditioner must be within reach of the length of its power cord to a properly grounded outlet Never allow the presence of any obstacles in the way entering the unit and leaving the unit air...

Page 13: ...hown in the figure on the right NOTE Only for models that are equipped with a wall mounted exhaust adapter and a set of screws with dowels for them 1 Make a hole in the wall with the required diameter...

Page 14: ...is in HEATING mode like a heat pump remove the lower drain plug from the rear panel of the air conditioner and install the drain connector universal 5 8 from the 3 4 drain hose purchased For models w...

Page 15: ...he water is drained remove the plug from the bottom drainage hole of the tray and drain the condensate After that put the plug in place and restart the air conditioner the error P1 should not be displ...

Page 16: ...of two filters top and bottom Bend the protective grill of the upper filter as shown in the figure below and then directly remove the filter behind it To remove the filter located behind the lower pr...

Page 17: ...nsate see page 14 Before storage let the air conditioner run for half a day in a warm room in the VENTILATION mode As a result the air conditioner will be thoroughly dried which will prevent or minimi...

Page 18: ...functioning properly The set temperature is too high Decrease the set temperature Air filter heavily clogged with dust Clean the air filter 3 The air conditioner is very noisy and vibrates during oper...