Features and specifications
3
Specifications
Voltage and wiring
(120V above ground)
240V AC single-phase:
L1, L2, and Safety Ground
208V AC 3-phase, wye-connected:
Any 2 phases, and safety ground.
240V AC 3-phase, delta-connected:
With center tap on one leg, use only the
two phases on either side of the center tap. The two phases must both
measure 120V AC to ground. Do not use the third leg (208V “stinger”).
Voltage and wiring
(230V above ground)
230V AC single-phase:
LINE, NEUTRAL, and EARTH.
Current and frequency
90A Circuit Breaker. The maximum current for the vehicle is 70A. At 240V,
this will be 17 kW maximum. At 230V, this will be 16 kW maximum. The
frequency is 50-60 Hz.
Cable length
Approximately 25’ (7.6 m)
Dimensions
Height: 14” (363 mm)
Width: 17” (432 mm)
Depth: 6” (152 mm)
Weight
Weight: 47 lbs (21 kg)
Operating temperature
-40°F to 122°F
-40°C to 50°C
Ratings and agency
approvals
NEMA 4 - outdoor use, watertight.
UL and CSA approved. CE compliant. FCC Part 15 compliant.
Home Connector Users Manual.book Page 3 Monday, April 26, 2010 12:38 PM