15
Troubleshooting
Issues
Possible Reasons
Solutions
Tescom Denki Co.,Ltd.
4217-1 Wada Matsumoto-City, Nagano, Japan
http://www.tescom-japan.co.jp/
Power will not turn on even
though the power switch is
pressed.
This means that the safety
device is working.
Refer to “Safety Device” on
page 13.
Power turns off during
operation.
Mist is not emitted.
Water tank is not attached
properly.
Please attempt to reattach the
water tank.
Spatula does not vibrate.
Head is not inserted properly.
Reinstall the head.
The charging lamp lights up
and goes out when the power
cord is bent.
The power cord is coming close
to be being broken.
Immediately stop use and
contact the store from which
the product was purchased.
There is another problem or failure.
Charging is not possible.
(Battery lamp lights up)
The end of the nickel-metal
hydride battery’s life is near.
Charging is not possible.
(Battery light does not light
up)
The power adapter is faulty.
Stops operating soon after
being charged.
The device was charging even
though a large amount of power
remained. (Extended charging)
Charge again after allowing
the rechargeable battery to sit
for a while. (Go to page 6)
8031-1