14
1
4
2
3
5
How to Remove the Nickel-Metal Hydride Battery
(when disposing)
Insert a flat-headed screwdriver into the
gap between the front and rear sections
of the body case to remove the rear side.
Press the power switch and mist button
simultaneously for 10 seconds or more.
Stop pressing when a beeping sound is
heard and check that the battery lamp
is flashing.
Charge until the battery lamp goes out.
Screw
Flat-headed screwdriver
Nickel-metal hydride battery
Water
tank
Rubber cap
Body
cap
Water tank
cover
Remove the screws (6).
Remove the body cap, water tank cover,
and water tank. Remove the rubber caps
(6) from the rear of the body.
Remove the connector for the lead wire
that connects the nickel-metal hydride
battery to the circuit board and pull out
the battery.
Lead wire
This is an explanation of how to dispose of the product. It is not an explanation to be used by
users to repair the product. This product cannot be replaced by users.
Lead wire
connector
●
Rechargeable Battery (Nickel-Metal Hydride Battery)
Please recycle the removed battery as required in your local area as it
contains precious resources.
Product name: Nickel-Metal Hydride Battery (Ni-MH)
Nominal voltage: 3.6 V
Quantity: 1
set