background image

56-21XX and 56-22XX Series

DOPSM2097X012

6

Section 2: Safety, Installation and  

Operations Precautions  

October 2016

requirements . Locate and construct vent lines to prevent condensation or gas 
accumulation . Make sure the vent outlet is not obstructed by rain, snow, ice, vegetation, 
insects, birds, etc . Do not interconnect vent lines; use separate lines if more than one 
vent is needed .

19 . 

Do not locate regulators, valves or accessories controlling flammable fluids near open 
flames or any other source of ignition.

20 . 

Some fluids when burning do not exhibit a visible flame. Use extreme caution when 
inspecting and/or servicing systems using flammable fluids to avoid death or serious injury 

to employees . Provide a device to warn employees of these dangerous conditions .

21 .  Many gases can cause suffocation . Make certain the area is well ventilated . Provide a 

device to warn employees of lack of Oxygen .

22 .  Never use oil or grease on these regulators, valves or accessories . Oil and grease are easily 

ignited and may combine violently with some fluids under pressure.

23 . 

Have emergency equipment in the area if toxic or flammable fluids are used.

24 . 

Upstream filters are recommended for use with all fluids.

25 . 

Do not bleed system by loosening fittings unless specified by Instruction Manual.

26 .  Prevent icing of the equipment by removing excess moisture from the gas .
27 . 

Always use proper thread lubricants and sealants on tapered pipe threads.

2.2 Installation

Do not open packaging until ready for installation or in a clean environment. Product is 
cleaned in accordance with CGA 4.1 and ASTM G93, Verification Type 1, Tests 1 and 2. With 
periodic verification of cleaning process to MIL-STD-1330D.

Make sure that the components and materials used in the fluid handling system are 
compatible with the fluid and have the proper pressure rating. Failure to do so can result in 
death, serious injury and/or property damage.

Inspect the regulator, valve, accessories and assembly for physical damage and contamination . 
Do not connect the regulator, valve, accessory or assembly if you detect oil, grease or damaged 
parts . If the regulator, valve, accessory or assembly is damaged, contact your local TESCOM 
representative to have the regulator cleaned or repaired .

2.3 

Repair Service

If a regulator or valve leaks or malfunctions, take it out of service immediately . You must have 
instructions before doing any maintenance . Do not make any repairs you do not understand . 

Have qualified personnel to make the repairs. Return any equipment in need of service to your 

Summary of Contents for 56-2100

Page 1: ...nd Service Manual DOPSM2097X012 October 2016 This manual is available in multiple languages online at www tescom com Do not attempt to select install use or maintain this product until you have read a...

Page 2: ......

Page 3: ...fety Installation and Operations Precautions 4 2 1 Regulators and Valves 4 2 2 Installation 6 2 3 Repair Service 6 Section 3 Introduction 7 Section 4 Specifications 8 Section 5 Drawings 8 5 1 Installa...

Page 4: ...rmation reaches the operator and stays with the product after installation Do not permit untrained personnel to install use or maintain this regulator valve or accessory Improper selection improper in...

Page 5: ...ressure to the system gradually avoiding a sudden surge of fluid or pressure shock to the equipment in the system 10 Regulators are not shut off devices Install a pressure relief device downstream of...

Page 6: ...ded for use with all fluids 25 Do not bleed system by loosening fittings unless specified by Instruction Manual 26 Prevent icing of the equipment by removing excess moisture from the gas 27 Always use...

Page 7: ...siveness and density of chemical fluids the fluid media and full system must be considered by the user when selecting a product This is required to ensure regulator performance user safety flow capabi...

Page 8: ...mum Inlet Pressure 56 22XX Series 10 000 psig 690 bar MaximumOutletPressure56 21XXSeries 14 800 psig 1034 bar MaximumOutletPressure56 22XXSeries 4000 psig 276 bar Operating Temperature All 0 to 165 F...

Page 9: ...ctober 2016 5 2 Installation Diagram for 56 22XX Series Letter call outs are referenced in the Installation and Start Up Procedures section of this manual OUTLET BLOCK VALVE INLET BLOCK VALVE 56 22XX...

Page 10: ...ury equipment damage or leakage due to escaping accumulated fluid or bursting of pressure containing parts may result if this regulator is Over pressured Used with incompatible process fluid Installed...

Page 11: ...ow through the system 10 Verify the regulator valve assembly s outlet pressure G to determine if there is any leakage If there is any leakage remove the 56 2XXX Series assembly for inspection and repa...

Page 12: ...one 2 Dubai UAE T 971 4 811 8443 F 971 4 886 5465 mea tescom emerson com www tescom com DOPSM2097X012 TescomCorporation 2015 2016 All RightsReserved Tescom is a business unit of Emerson Process Manage...

Reviews: