BASIC CONTRA-INDICATIONS FOR APPLICATION 

 

„

 Convulsive state, epilepsy. 

„

 Traumas and brain tumors, infectious diseases of central nervous system 

(acute stage). 

„

 Hypertensive disease stage III, hypertensive crisis. 

„

 Hydrocephaly. 

„

 Acute psychiatric disorders. 

„

 Thyrotoxicosis. 

„

 Atrial fibrillation. 

„

 Skin lesions at the site of applied electrodes. 

„

 Implanted cardiostimulators. 

„

 Age under 5 years. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

20

CLEANING AND CLEANSING OF UNIT AND HEADBAND

 

In case of individual use the Unit and headband should not obligatorily be 
disinfected. If necessary the exterior of the Unit can be cleaned by using 70% 
alcohol. 
A headband may be washed depending on frequency of use. For this, 
headband should be disconnected from the wire that plugs it into the Unit, as 
well as from electrodes which are made of conductive rubber. After a 
headband was washed and dried up wire and electrodes must be 
reconnected, as depicted on page 10. 

 

TECHNICAL SUPPORT 

Implies before-the-fact battery replacement or charging of accumulator. Other 
technical support should not be performed at home. 

RECYCLING  

The used batteries are not considered as household rubbish, and must be 
recycled at the battery collection points. 
The Unit contains no materials hazardous to human or environment. It does not 
need special precautions during recycling. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DOCTOR TES-03

Page 1: ...ere awarded with Grand Prix in the nomination High Impact Invention Ten thousand professional TES Units have been successfully applied both in Russia and abroad Aside from mentioned prizes they have won many other Russian and foreign top awards V P L e b e d e v D M S c P r of e s s o r Rus Acad Natur Sci Academician laureate of the state USSR Prize laureate of the Government of the RF Prize Honou...

Page 2: ...to fail which is followed by appearance of acute and chronic diseases pain syndromes disturbed healing processes compromised immunity psychosomatic disturbances which influence a quality of dreams performance and quality of life as a whole 4 What complaints symptoms and conditions might be associated with an endorphin deficiency Acute headache of unreasonably high intensity Unexplained repeated he...

Page 3: ...cco and alcohol addiction normalization of the impaired stool passage SAFETY PRECAUTIONS Before reading the User s Guide it is forbidden to use the Unit Use the Unit strictly as intended Follow the work sequence as it is described in Paragraphs Work sequence and Carrying out Procedure In case a nonrepairable failure was found which is not mentioned in the Paragraph Common Troubles And Remedies con...

Page 4: ...ee Figure 3 socket of the headband electrodes 19 to the hole at the upper end face 8 in the Unit Plug male connectors 18 in the adhesive electrodes 16 17 as shown in the Figure 3 Frontal electrode 16 has the size 40х80 mm and retromastoid electrodes 40х40 mm After that close the frontal electrode 16 onto any of retromastoid electrodes 17 by holding them with flat surfaces 15 Press button 3 and hol...

Page 5: ...irritation discomfort or no adaptation at all magnitude of current should be reduced For this press button 2 until the uncomfortable sensation is disappeared It is recommended that during the 1st session stimulating current should not be higher than 0 5 mA For further procedures it should not exceed higher than 1 5 mA see pages 16 19 After procedure completed in 30 minutes the Unit will automatica...

Page 6: ...cause of identical mode of action it is useless to simultaneously apply TES therapy together with acupuncture Acupuncture may be applied before or after TES sessions as an additional therapeutic approach to strengthen effect from treatment TES therapy can be well combined with psychotherapy Moreover both Of them can compliment each other and potentiate therapeutic effect 12 Due to this additive ef...

Page 7: ...licit habituation addiction or dependency During TES treatment after the first sessions most patients start to feel improved overall condition sleeping mood Pain sense is weakened or fully vanished healing of damaged tissues is accelerated However if during TES therapy sessions patient started to feel a subjective deterioration of well being the procedure should be stopped After that there must be...

Page 8: ...f post traumatic stress Stammering Insomnia performance decrement in healthy people 10 12 sessions per course once a day or every other day for 30 min Current up to 1 5m A R e p e a t c o u r s e i n 3 4 months 16 Cardiology Hypertension disease stage I II Hypotension syndromes Neurocirculatory vegetative vascular dystonia Patients recovering after uncomplicated heart attack 10 12 sessions per cou...

Page 9: ...up to 1 5 mA Repeat course according to indications it may correspond as close as possible to the previous one 18 Obstetrics and Gynecology Menstrual disorders in pubertal girl Premenstrual syndrome Menstrual disorders and endocrine infertility under obligatory medical supervision Vomiting during recent pregnancy Menopausal disorders 10 15 sessions per course once a day for 30 min Current up to 1 ...

Page 10: ... the Unit can be cleaned by using 70 alcohol A headband may be washed depending on frequency of use For this headband should be disconnected from the wire that plugs it into the Unit as well as from electrodes which are made of conductive rubber After a headband was washed and dried up wire and electrodes must be reconnected as depicted on page 10 TECHNICAL SUPPORT Implies before the fact battery ...

Page 11: ...heck battery connection replace battery or charge accumulator The Unit is being switched on auto checking procedure is in process TES session proceeds fine However during the session indicator Battery blinks Battery accumulator capacity started to run low during procedure Finish procedure and then replace battery or charge accumulator The Unit is being switched on auto checking procedure is in pro...

Page 12: ... free of charge repair service or to replace Unit if repair is impossible Operating life 5 years since date of manufacture After warranty period has expired the Manufacturer will charge for providing with repair service Warranty and post warranty repair is performed by the Manufacturer or by certified district service centers ACCEPTANCE CERTIFICATE Unit DOCTOR TES 03 has been manufactured and cert...

Reviews: