background image

 

11 

of light flickering behind closed eyes. It is important to keep this sensing at 
the same level during the whole procedure, and avoid too strong reaction. If 
necessary current intensity may be adjusted. 

In case when a therapeutic effect after first TES sessions was detected, 

all further procedures should be carried out under the same value of current 
intensity that provided it. Further increase of current is optional.  

Starting from the 2

nd

 procedure standard duration can be extended for 

up to 30 min (controlled by the in-built timer, stops automatically). TES 
therapy can be applied once a day or every other day. In case of severe 
pain syndromes it is possible to perform TES sessions twice a day (up to 3 
times a day) with 6-12 hours interval until pain symptoms are relieved. 
Usually, positive effect is obtained after the second TES-procedure.  In 
case pain syndrome is not managed after 5-6 sessions TES-therapy should 
be stopped, and patient must be further examined to verify or correct 
diagnosis as well as indications for use. Consult to your attending physician. 

It is recommended that after each procedure patient has a rest for 15–

20 min., especially for those who have unstable blood pressure. In 
addition, for these patients gently massage jugular area of the neck. 

Standard course contains 6–12 sessions. If necessary it can be repeated 

in 2–3 months. However, in case of new indications for use or diseases a 
new course may be performed in 

2–3 

weeks. For treatment of acute 

diseases or relapses of chronic cases TES-therapy must be applied until 
main symptoms will be eliminated, meaning that it may be shortened only for 
up to 4-6 procedures. In case of chronic smoldering course of pathology 
(remission stage) TES therapy after the first session may be repeated in 3-4 
months, for up to three times a year. Total number of TES sessions is 
prescribed by a physician, but usually it should not exceed more than 50-60 
procedures a year. 

Combination of TES-therapy with other therapeutic approaches 

 

TES sessions are well combined with traditional therapeutic methods: 

medicated, physiotherapeutic, balneological, manual therapy etc. It is 
well combined virtually with all medicines. Due to the intrinsic mode of 
action TES therapy allows to significantly reduce usage of drugs or 
completely avoid them, in particular, analgetic, antidepressant drugs, 
immunomodulators, hormonal medicines etc. However, such changes in 
prescribed medications must be authorized and supervised by 
physician only. Because of identical mode of action it is useless to 
simultaneously apply TES therapy together with acupuncture. Acupuncture 
may be applied before or after TES sessions as an additional therapeutic 
approach to strengthen effect from treatment. 

TES-therapy can be well combined with psychotherapy. Moreover, both Of 

them can compliment each other and potentiate therapeutic effect. 

 

12

Due to this additive effect an audio session with music-and-linguistic 

persuasion was developed (CD-disk is enclosed to Standard Set). 

Audio session may be listened simultaneously with TES-therapy or 

separately as a complimentary means of psychotherapy. 

Recommendations on diet 

 

It is well-known that virtually any kind of therapy is accompanied with 

a specific balanced diet. The same is true for healthy people. Due to the 
fact that TES-therapy improves patient’s metabolism it is very important 
to eat a healthy diet, containing nutrients of sufficient quantity and 
quality. 

The most obvious signs of unhealthy diet are overweight or apparent 

underweight. Usually overweight represents a consequence of the 
ongoing stress situations, which are offset by excessive food 
consumption in order to get some satisfaction from meal or alcohol. 
However, it does not remove a cause of stress, but instead they gain 
extra kilos weight that brings new problems. 

Additionally, hearts works harder, and it can not as easy as before to 

pump out blood through the enlarged vascular network, which is getting 
clogged with cholesterol. Musculoskeletal system experiences increased 
loads, often becoming overworked. Gut suffers from incomplete depletion, 
as an extra amount of food exceeds its capacity. Eventually it leads to 
deposition of intestinal waste inside it that facilitates growth of harmful 
toxin-producing microorganisms. 

As a result, people with imbalanced diet suffer from increased 

tiredness, soreness, ending up with premature aging and failures of 
different functional systems. Moreover, frequently condition is deteriorated 
with self-treatment when patients take tablets, pills etc. basing only on 
commercials. Thus, such unhealthy conditions substantially obstruct normal 
functioning of the body. 

On the contrary, it is well known that healthy diet contributes much to 

strengthen body and help it to manage with numerous challenges of 
environment. 

Here we refer to brief recommendations on healthy diet which may not 

only avoid consequences linked to overweight, but increase efficacy of 
TES-therapy as well. 

 
R e c o m m e n d e d   f o o d   t h a t   f a c i l i t a t e s   t o   i n c r e a s e d  

e n d o r p h i n   r e l e a s e   d u r i n g   T E S - t h e r a p y :

 

–  Farmer cheese, fermented milk products; 
–  Food enriched in vegetable protein (soybean, rice, legumes) and 

animal protein (hen, veal, lean fish); 

Summary of Contents for DOCTOR TES-03

Page 1: ...ere awarded with Grand Prix in the nomination High Impact Invention Ten thousand professional TES Units have been successfully applied both in Russia and abroad Aside from mentioned prizes they have won many other Russian and foreign top awards V P L e b e d e v D M S c P r of e s s o r Rus Acad Natur Sci Academician laureate of the state USSR Prize laureate of the Government of the RF Prize Honou...

Page 2: ...to fail which is followed by appearance of acute and chronic diseases pain syndromes disturbed healing processes compromised immunity psychosomatic disturbances which influence a quality of dreams performance and quality of life as a whole 4 What complaints symptoms and conditions might be associated with an endorphin deficiency Acute headache of unreasonably high intensity Unexplained repeated he...

Page 3: ...cco and alcohol addiction normalization of the impaired stool passage SAFETY PRECAUTIONS Before reading the User s Guide it is forbidden to use the Unit Use the Unit strictly as intended Follow the work sequence as it is described in Paragraphs Work sequence and Carrying out Procedure In case a nonrepairable failure was found which is not mentioned in the Paragraph Common Troubles And Remedies con...

Page 4: ...ee Figure 3 socket of the headband electrodes 19 to the hole at the upper end face 8 in the Unit Plug male connectors 18 in the adhesive electrodes 16 17 as shown in the Figure 3 Frontal electrode 16 has the size 40х80 mm and retromastoid electrodes 40х40 mm After that close the frontal electrode 16 onto any of retromastoid electrodes 17 by holding them with flat surfaces 15 Press button 3 and hol...

Page 5: ...irritation discomfort or no adaptation at all magnitude of current should be reduced For this press button 2 until the uncomfortable sensation is disappeared It is recommended that during the 1st session stimulating current should not be higher than 0 5 mA For further procedures it should not exceed higher than 1 5 mA see pages 16 19 After procedure completed in 30 minutes the Unit will automatica...

Page 6: ...cause of identical mode of action it is useless to simultaneously apply TES therapy together with acupuncture Acupuncture may be applied before or after TES sessions as an additional therapeutic approach to strengthen effect from treatment TES therapy can be well combined with psychotherapy Moreover both Of them can compliment each other and potentiate therapeutic effect 12 Due to this additive ef...

Page 7: ...licit habituation addiction or dependency During TES treatment after the first sessions most patients start to feel improved overall condition sleeping mood Pain sense is weakened or fully vanished healing of damaged tissues is accelerated However if during TES therapy sessions patient started to feel a subjective deterioration of well being the procedure should be stopped After that there must be...

Page 8: ...f post traumatic stress Stammering Insomnia performance decrement in healthy people 10 12 sessions per course once a day or every other day for 30 min Current up to 1 5m A R e p e a t c o u r s e i n 3 4 months 16 Cardiology Hypertension disease stage I II Hypotension syndromes Neurocirculatory vegetative vascular dystonia Patients recovering after uncomplicated heart attack 10 12 sessions per cou...

Page 9: ...up to 1 5 mA Repeat course according to indications it may correspond as close as possible to the previous one 18 Obstetrics and Gynecology Menstrual disorders in pubertal girl Premenstrual syndrome Menstrual disorders and endocrine infertility under obligatory medical supervision Vomiting during recent pregnancy Menopausal disorders 10 15 sessions per course once a day for 30 min Current up to 1 ...

Page 10: ... the Unit can be cleaned by using 70 alcohol A headband may be washed depending on frequency of use For this headband should be disconnected from the wire that plugs it into the Unit as well as from electrodes which are made of conductive rubber After a headband was washed and dried up wire and electrodes must be reconnected as depicted on page 10 TECHNICAL SUPPORT Implies before the fact battery ...

Page 11: ...heck battery connection replace battery or charge accumulator The Unit is being switched on auto checking procedure is in process TES session proceeds fine However during the session indicator Battery blinks Battery accumulator capacity started to run low during procedure Finish procedure and then replace battery or charge accumulator The Unit is being switched on auto checking procedure is in pro...

Page 12: ... free of charge repair service or to replace Unit if repair is impossible Operating life 5 years since date of manufacture After warranty period has expired the Manufacturer will charge for providing with repair service Warranty and post warranty repair is performed by the Manufacturer or by certified district service centers ACCEPTANCE CERTIFICATE Unit DOCTOR TES 03 has been manufactured and cert...

Reviews: